13.07.2015 Views

1066 Liquid Analytical Transmitter - Emerson Process Management

1066 Liquid Analytical Transmitter - Emerson Process Management

1066 Liquid Analytical Transmitter - Emerson Process Management

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>1066</strong> Instruction Manual Section 10: HART CommunicationLIQ_MAN_<strong>1066</strong> September 2013<strong>1066</strong> Temperature Parametersrtd_offsetThe temperature offset resulting from a temperaturecalibration.rtd_slopeThe slope (dimensionless) resulting from a twopoint temperature calibration. (Valid for cellconstants < 0.02 1/cm)temp_comp_modeSelects automatic or manual temperaturecompensation.manual_temperatureIf manual temperature compensation is chosen,provides a constant temperature value used by thetransmitter.Type Enumeration / Range Read/Write DefaultFLOAT R / W 0FLOAT R / W 1ENUMManualAutomaticR / WAutomaticFLOAT R / W 25.0 C<strong>1066</strong> pH/ORPzero_offsetThe zero offset of a pH sensor resulting from a calibration.pH_slopeThe slope of a pH sensor resulting from a buffer calibration.zero_offset_limitThe maximum value of the zero offset allowed for a successfulcalibration.min_pH_slopeThe minimum value of the slope allowed for a successfulcalibration.max_pH_slopeThe maximum value of the slope allowed for a successfulcalibration.pH_stabilization_timeThe period of time used to determine stability of a pH sensorduring automatic calibration.pH_stabilization_valueThe pH change used to determine stability of a pH sensorduring automatic calibration.pH_buffer_standardThe types of pH buffers available for automatic calibration.preamp_locationThe location of the preamplifier in a pH measurement.reference_impedance_levelConfigures the transmitter to use reference electrodes withimpedances less than 500 kohm (low) or greater than 500kohm (high).pH_solution_temperature_correctionConfigures the transmitter to correct the pH measurementfor changes in the pH of the solution with temperature.pH_solution_temperature_coefficientThe coefficient used to correct solution pH when using customsolution pH temperature correction.Type Enumeration / Range Read/Write DefaultFLOAT R / W 0.0 mVFLOAT 40 -- 62 mV/pH R / W 59.16 mV/pHFLOAT R / W 60FLOAT 40 -- 62 mV/pH R / W 40 mV/pHFLOAT 40 -- 62 mV/pH R / W 62 mV/pHFLOAT 0 -- 99 seconds R / W 10 secondsFLOAT 0.01 -- 1.0 pH R / W 0.02 pHENUMENUMENUMENUMStandard / NistDIN 19267IngoldMerckFisheranalyzersensor / J-boxLowHighOffultra pure waterhigh pHammoniacustomR / WR / WR / WFLOAT -9.999 -- 9.999 pH/deg C R / WStandard /NistLowOff0.000pH/degCHART Communications 113

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!