Fort Nelson NRRM MECHANICAL SECTION 15250<br />

Airport Terminal Building INSULATION Page: 5<br />

Washroom Renovations<br />

Jacket:<br />

Insulation shall be protected with a minimum 5mm (0.020”) thick aluminum<br />

jacket attached within 12mm stainless steel band and/or 12mm x 20mm stainless<br />

steel Robertson screws.<br />

Application<br />

Insulation<br />

Aluminum:<br />

On rectangular duct, secure insulation using weld pins (cup head type) at 300mm<br />

on centre (min. 2 rows per side). On round duct, secure insulation using<br />

stainless steel banding at 300 mm on centre.<br />

On rectangular duct, all circumferential and longitudinal seams should<br />

incorporate a standing lap and/or drive cleat system and be installed in a manner<br />

that will prevent water transmission. Cross breaks should be incorporated to add<br />

additional stiffness to the jacket. Screws should not be used where the insulation<br />

vapour barrier can be penetrated. Seal all penetrations of aluminum jacket using<br />

a suitable exterior grade silicone caulking.<br />

7. Duct insulation adhesives and coatings shall be non-toxic as defined by W.C.B. Regulations.<br />

END of SECTION 15250<br />