09.12.2012 Views

1 - Nuclear Sciences and Applications - IAEA

1 - Nuclear Sciences and Applications - IAEA

1 - Nuclear Sciences and Applications - IAEA

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

,oV<br />

10<br />

10'<br />

10<br />

<strong>IAEA</strong>-CN-50/A-IV-3 243<br />

II11111 11 11 11 1111111 I I 11 11 1111 I 1111 11 I 1111 11 1111 11<br />

4 6<br />

10<br />

dBr<br />

6z<br />

(G-cm ')<br />

FIG. 3. Dependence of increase in vertical instability on — dBJdz: 1: without passive stabilization;<br />

2: with stabilizing coil only; 3: with chamber only; 4: with chamber <strong>and</strong> coil (Ip = 100 kA).<br />

cally unstable at the start <strong>and</strong> for R > 106 cm it is horizontally unstable. Stable<br />

equilibrium is only possible within a narrow zone near R « 106 cm. The short time<br />

constant of the chamber requires a fast <strong>and</strong> powerful control system for the major<br />

radius equilibrium. At the end of December 1987, the TSP device was mounted <strong>and</strong><br />

pumped out down to 10" 4 Pa. By that time, only one flywheel generator had been<br />

mounted <strong>and</strong> started up so that the device could only operate in rather poor<br />

conditions. Therefore, to increase the discharge frequency, we used condenser<br />

batteries as a power supply rather than the flywheel generator. For rather low toroidal<br />

fields (about 0.2 T on the radius of 106 cm, 0.8 T on the winding) a breakdown <strong>and</strong><br />

a current of up to 10 kA for one-turn voltages of less than 30 V <strong>and</strong> an initial<br />

deuterium pressure of 10~ 2 Pa were obtained. Measurements of the vertical<br />

magnetic field distributions <strong>and</strong> current distributions in the chamber were conducted;<br />

they showed good agreement with the calculations. Besides, an appreciable radial<br />

component of the magnetic field of several gauss, subject to compensation, was<br />

found. Equilibrium control system tests have shown that the required fast action is<br />

not ensured <strong>and</strong> the column cannot be maintained in equilibrium in the chamber,<br />

which has, according to the measurements, a time constant of about 100 s. If this<br />

system is to be upgraded to design parameters, it has to be modified significantly,

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!