Views
1 week ago

ArabPTnetCatalouge

Chattanooga ® Vectra ®

Chattanooga ® Vectra ® GENiSYS Laser ■ choice of 8 interchangeable laser diode and cluster applicators with power ranging from 100-1440mW ■ electronic signature recognition allows each laser applicator to be used in a "plug-and-use" format ■ laser therapy can be controlled from the laser applicator ■ lightweight design, with batterypowered option and custom designed mobile carrying bag (sold separately) make transport easy ■ laser protective eyewear included (2 ea) Vectra ® GENiSYS Transport Laser unit 00-2784 Laser (w/out applicator) 00-2896 Laser w/cart & adapter (w/out applicator) Laser Diode Applicators and kits 02-7840 (1) 850 nm Laser Diode @ 100 mW 02-7841 (1) 850 nm Laser Diode @ 200 mW 02-7805 (1) 820 nm Laser Diode @ 300 mW 02-7811 9 Diode Cluster Applicators kit (5) 850 nm Laser Diodes @ 100 mW each (4) 670 nm LED Diodes @ 10 mW each 02-7812 9 Diode Cluster Applicators kit (5) 850 nm Laser Diodes @ 200 mW each (4) 670 nm LED Diodes @ 10 mW each 02-7814 13 Diode Cluster Applicators kit (3) 850 nm Laser Diodes @ 100 mW each (3) 950 nm SLD Diodes @ 15 mW each (7) 670 nm LED Diodes @ 10 mW each 02-7816 13 Diode Cluster Applicators kit (3) 850 nm Laser Diodes @ 200 mW each (3) 950 nm SLD Diodes @ 15 mW each (7) 670 nm LED Diodes @ 10 mW each ■ continuous and pulsed treatment modes ■ real time feedback of dosage delivered by easy-to-read graphic LCD display ■ selection of clinical indications & user defined protocols 02-7808 33 Diode Cluster Applicators kit (5) 850 nm Laser Diodes @ 200 mW each (8) 880 nm SLD Diodes @ 25 mW each (8) 950 nm SLD Diodes @ 15 mW each (12) 670 nm LED Diodes @ 10 mW each accessories 02-7525 laser protective eyewear (each) 02-7478 transportable battery pack (not shown) 02-7133 Vectra ® GENiSYS Therapy System carry bag 02-7467 Vectra ® GENiSYS transportable carry bag 00-2780 Vectra ® GENiSYS cart 00-2883 cart adapter (Blue) 00-2758 laser module laser and applicator sold separately Mettler ® Laser SysStim 540 (1) laser applicator over laser output sensor showing visible proof of laser activity; (2) laser applicator showing one laser diode at 785 nm surround by 3 LEDs at 470nm; (3) cluster applicator showing 12 SLDs at 950 nm with seven LEDs at 660 nm ■ light therapy device uses both true Laser and Infrared (cluster) ■ change treatment time, continuous/pulsed modes and intensity with ease ■ treatment parameters are displayed on the LED displays and controlled via the membrane keypad ■ control output from both laser and cluster probes ■ store applicators in integrated holders when not in use ■ 785 nm laser probe emits visible blue LEDs that illuminate the treatment field ■ 5.5 lb (2.5 kg), 4.7"H x 9.4"D x 9.4"W, (12cmH x 24cmD x 24cmW) ■ includes battery ■ built-in protocols with additional memory for userdefined protocols ■ built-in Laser tester to assure proper output ■ protective glasses included Laser Sys*Stim 540 1 2 3 Laser Sys*Stim 540 unit 13-3200 Sys*Stim 540L with 785 nm applicator 13-3201 Sys*Stim 540C with 950 nm SLD, 660 nm LED cluster 13-3202 Sys*Stim 540LC with 785 nm applicator, 950 nm SLD, 660nm LED cluster accessories 13-3210 Sys*Stim 540 785 nm applicator 13-3211 Sys*Stim 540 660 nm SLD, 950 nm LED cluster applicator 13-3212 Sys*Stim 540 protective UVex glasses (1 pair) treatment modalities (minimum advertised price applies) Fabrication Enterprises Website www.ArabPT.net Direct Consult No. +966564401554/+966583943888 E-Mail info@ArabPT.net 129

Amrex® ultrasound Amrex ® ultrasound units ■ continuous output mode U/20 ultrasound unit ■ standard or quick connect transducer ■ 12 watt 1.0 MHz U/50 ultrasound unit* ■ continuous & pulsed output modes ■ can be combined with Stim unit* ■ standard or quick connect transducer ■ 20 watt 1.0 MHz standard transducer with 10cm head 13-3110 QuickConnect transducer with 10cm head 13-3103 with 5cm head 13-3106 with both head 13-3107 Amrex ® standard transducer with 10cm head 13-3111 QuickConnect transducer with 10cm head 13-3100 with 5cm head 13-3101 with both heads 13-3105 ultrasound/ stim combo units * use with Amrex ® stim units on page 131 for combination therapy US/50 with low volt U/HVG50 with low and high volt treatment modalities ■ single channel LV with surge, tetanize and pulsation ■ 20 watts, pulsed or continuous output modes standard transducer 1.0 MHz 1.0 & 3.3 mHZ with 10cm head 13-3112 13-3112C QuickConnect transducer with 10cm head 13-3144 13-3144C with 5cm head 13-3156 13-3156C with both heads 13-3157 13-3157C ■ dual channel HV with reciprocal and ramped surge ■ LV galvanic with variable surge and reverse polarity ■ 20 watts, pulsed or continuous output modes standard transducer 1.0 MHz 1.0 & 3.3 mHZ with 10cm head 13-3113 13-3113C QuickConnect transducer with 10cm head 13-3145 13-3145C with 5cm head 13-3160 13-3160C with both heads 13-3161 13-3161C ■ dual channel LV AC with surge, tetanize and pulsation US/54 with low volt ■ 20 watts, pulsed or continuous output modes US/752 with high volt ■ dual channel HV with variable frequency 1-160 pps, reciprocal & ramped surge (2-90 seconds), patient interrupt switch and adjustable “on/off” ■ 20 watts, pulsed or continuous output modes standard transducer 1.0 MHz 1.0 & 3.3 mHZ with 10cm head 13-3114 13-3114C QuickConnect transducer with 10cm head 13-3146 13-3146C with 5cm head 13-3158 13-3158C with both heads 13-3159 13-3159C standard transducer 1.0 MHz 1.0 & 3.3 mHZ with 10cm head 13-3115 13-3115C QuickConnect transducer with 10cm head 13-3153 13-3153C with 5cm head 13-3154 13-3154C with both heads 13-3155 13-3155C 130 Website www.ArabPT.net Direct Consult No. +966564401554/+966583943888 Fabrication Twitter Enterprises @ArabPT

Digital Catalog
Dynamic_96pp_Catalogue_reduced_07-06-16
Vacucaddy - Online Brochure
Cassellie_Spring2017_brochure_reprint_UNSECURED