OUTSIDE MOUNT 90º CORNER WINDOW<br />

1. Measure outside from the architrave to the back of<br />

where the frame would sit, at the front edge of the<br />

window as shown left.<br />

2. A+B = total window width.<br />

3. This is the size you enter on the order as finish size<br />

4. The total width of A is the location of corner post<br />

5. If a divider rail is required, measure from the floor or<br />

outside of architrave to the centre of the required<br />

divider rail location. Remember rails could vary up<br />

to 40mm if not specified critical.<br />

6. If a T post is required, measure from the outside of<br />

architrave at left to the centre of the T post<br />

7. T post location in area B would be A + Post position<br />

INSIDE MOUNT TRACK BIFOLDS<br />

Headboards are supplied as standard for track bifolds with top track attached. Sideboards and<br />

bottom boards are optional however floor track is mandatory with no option to waive warranty.<br />

Track bifolds can be installed inside mount and standard deductions are taken at the factory to<br />

allow for fitting. If semi recess mount is required with shorter returns, you must specify this in notes.<br />

Ensure there is enough clearance for doorhandles, track layouts are specified on the next page.<br />

1. Measure the recess depth<br />

2. Measure the diagonal to check for squareness.<br />

If the diagonal sizes vary by more than 10mm, an outside mount is preferable<br />

3. Measure inside width in at least 3 places (top, centre and bottom)<br />

4. Provide the smallest width size as window size, do NOT take a deduction<br />

5. Measure inside height in at least 3 places (left, centre and right)<br />

6. Provide the smallest height size as window size, do NOT take a deduction<br />

7. If a divider rail is required, measure from the inside bottom to the centre of the required<br />

divider rail location. Remember rails could vary up to 40mm if not specified critical.<br />

OUTSIDE MOUNT TRACK BIFOLDS<br />

Headboards are supplied as standard for track bifolds with top track attached. Sideboards and<br />

bottom boards are optional however sideboards are recommended for outside mount to<br />

provide better light block. It is common practice to mount headboard and sideboards outside<br />

of the architrave hard up against the wall. For this layout, you will need to add extra to your sizes<br />

to allow for boards. Ensure there is enough clearance for doorhandles. Track layouts are specified<br />

on the next page.<br />

1. Measure outside of architrave width in at least 3 places (top, centre and bottom)<br />

2. Add at least 38mm for sideboards (if required) as finish size<br />

3. Measure outside of architrave height in at least 3 places (left, centre and right)<br />

4. Add at least 19mm for headboard as finish size<br />

5. If a divider rail is required, measure from the floor or outside of architrave to the centre<br />

of the required divider rail location. Remember rails could vary up to 40mm if not<br />

specified critical.<br />