Freezer compartment<br />

[2]<br />

Compressor does not operate<br />

[3]<br />

Filter board<br />

CN1 CN12<br />

Noise filter<br />

Poor cooling<br />

1 Is the set temperature of freezer compartment set to “High”?<br />

Yes<br />

2<br />

3<br />

Does cool air come out of air outlet when opening the refrigerator<br />

compartment door and attaching a magnet bar on the door switch ?<br />

Yes<br />

Check freezer compartment thermistor.<br />

Dip freezer compartment thermistor into ice water (0 ), and<br />

measure the resistance between terminal (white) and<br />

(white) by detaching 4-pin connector at the left-back bottom of<br />

vegetable compartment.<br />

•Resistance at 0 :approx. 6~7k .<br />

Defective thermistor<br />

Replace freezer compartment thermistor<br />

Not cooling at all (In case any error codes doesn’t appear as shown in page 29,30 even though Ice select switch is pressed for 5 seconds)<br />

Does AC 230V run between and , terminals<br />

of CN1 on filter board?<br />

Yes<br />

Does AC 230V run between and , terminals<br />

of CN12 on filter board?<br />

Yes<br />

Detach each connector CN2A on<br />

control board check the continuity<br />

between terminals and<br />

respectively.<br />

(Check if there is a short or open<br />

circuit in the motor protector.)<br />

Continuity detected<br />

Detach connector CN50G on control<br />

board and check the resistance<br />

respectively between terminals of<br />

, and :approx. 9.3<br />

Continuity detected<br />

Check the error display of selfcheck<br />

after turning on and off the<br />

power supply.<br />

With all the connectors connected.<br />

Inverter-related parts may be<br />

defective. Conduct ice making<br />

test operation. (See page 29,30<br />

for error codes.)<br />

No<br />

continuity<br />

No<br />

No<br />

Control board<br />

6-pin connector in machine chamber<br />

CN2A CN50G<br />

Control board<br />

28<br />

No<br />

No<br />

Normal<br />

CN7S<br />

Abnormal<br />

Set the temperature to “High”.<br />

Proceed to “The refrigerator fan motor does not work.”<br />

When compressor<br />

operates, display<br />

indicates E41 as a<br />

result of self-check.<br />

M<br />

Compressor<br />

M Motor<br />

protector<br />

Normal<br />

Abnormal<br />

Normal<br />

4-pin connector<br />

Yes<br />

Is refrigerator in the demonstration mode? Release the demonstration mode. (See page 11.)<br />

No<br />

No<br />

continuity<br />

Inspect power-supply wiring such as power cord and<br />

breaker etc.<br />

Replace the filter board.<br />

Motor protector (open circuit)<br />

By measuring the resistance,<br />

ensure that the circuit is open.<br />

Disconnect 6-pin connector<br />

in machine chamber to check<br />

resistance between terminals of<br />

, and : approx. 9.3<br />

Abnormal<br />

Measure the resistance of compressor’s<br />

winding between terminals<br />

of black, white, and red :<br />

approx. 9.3<br />

Check connector contact.<br />

Exchange the unit<br />

Replace solenoid<br />

valve coil.<br />

Freezer<br />

compartment<br />

thermistor<br />

Replace the lead wire<br />

assembly (Lead wire of<br />

compressor)