Inverter-related indication “Compressor does not operate”<br />

Error<br />

code<br />

Abnormality Possible cause Symptom Treatment<br />

E50<br />

E51<br />

E52<br />

E53<br />

Trouble of<br />

inverter circuit<br />

Bus-bar<br />

voltage is<br />

abnormal.<br />

Trouble of<br />

inverter software<br />

reset function<br />

•Abnormal startup<br />

•Abnormal<br />

synchronization<br />

•Trouble of<br />

overcurrent<br />

detection<br />

•When there is<br />

any trouble in the<br />

circuit which<br />

detects phase<br />

current of compressor.<br />

•Power supply<br />

voltage is<br />

abnormal.<br />

•Defective reactor<br />

on the N/F board<br />

•When the inverter<br />

driving software<br />

malfunctions due<br />

to electric noise.<br />

•Compressor<br />

motor gets locked.<br />

•Defective circuit<br />

on control board<br />

•Defective contact<br />

of CN50G on<br />

control board<br />

•Defective contact<br />

of machine<br />

chamber 6-pin<br />

connector<br />

Compressor<br />

does not<br />

rotate.<br />

Compressor<br />

does not<br />

rotate.<br />

Compressor<br />

does not<br />

rotate.<br />

Compressor<br />

does not<br />

rotate.<br />

29<br />

Replace the control board.<br />

Check the error code by performing the ice making test operation.<br />

E52 display again.<br />

Start<br />

Measure the voltage of<br />

power supply.<br />

Does AC 230V run<br />

between CN2A terminals<br />

and , on<br />

the control board?<br />

(See page 40.)<br />

Replace the control board.<br />

253V or more<br />

207V or<br />

more<br />

Arrange<br />

power supply<br />

to obtain<br />

the rated<br />

voltage,<br />

207~253V.<br />

Arrange power supply to make the voltage<br />

within 253V and conduct the following<br />

checks.<br />

No<br />

Check the<br />

connection<br />

between filter<br />

board and<br />

control board.<br />

Yes Normal<br />

Replace the Replace the<br />

control board. filter board.<br />

Abnormal Connect<br />

them<br />

properly.<br />

Unplug the power cord and wait more than 10 minutes then plug it again.<br />

Start<br />

Disconnect 6-pin<br />

connector in<br />

machine chamber<br />

to check resistance<br />

between<br />

each terminal of<br />

, and : Are<br />

they approx. 9.3<br />

(20 )?<br />

Yes<br />

*Is compressor<br />

energized at<br />

startup?<br />

Exchange<br />

the unit.<br />

Measure the<br />

resistance<br />

of compres-<br />

No error code display<br />

Explan to customer<br />

No sor’s winding No<br />

between each<br />

terminal of<br />

, and : Are<br />

they approx. 9.3<br />

(20 )?<br />

Yes<br />

*Replace lead wire assembly C.<br />

No<br />

Check the connection of the<br />

connector CN50G on the<br />

control board or the machine<br />

chamber 6-pin connector.<br />

Yes Normal<br />

Replace the<br />

control board.<br />

*If control board is normal, compressor is energized<br />

every 10 minutes.<br />

Compressor vibrates at startup when it is being energized.<br />

Touch it with your hand to check.<br />

Abnormal<br />

Exchange<br />

the unit.<br />

Connect them<br />

properly.