Components/<br />
Part Name<br />
LED for bacteria<br />
removal from<br />
water tank<br />
(12V DC)<br />
Vegetable compartmentphotosynthesis,<br />
UV<br />
LED, Blue LED<br />
(12V DC)<br />
Check Method and Criterion<br />
6-7 TEST POINT DIAGRAM OF FILTER BOARD<br />
<strong>MR</strong>-<strong>G57N</strong>-<strong>NZ</strong><br />
AC 230V<br />
Timing in<br />
making contact<br />
Abnormal<br />
condition<br />
LED<br />
Timing in<br />
making contact<br />
Abnormal<br />
condition<br />
•After water is supplied to the ice tray.<br />
•After the ice level sensor lever detects that ice storage<br />
becomes full.<br />
•While the door is kept open for maximum of 5 minutes.<br />
When the door is opened, LED goes out within 5 minutes.<br />
Make sure if the connector is securely connected.<br />
Note: LED cannot be replaced individually because<br />
it is embedded in the tank holder.<br />
Photosynthesis LED 3 pieces + UV LED 1 piece + Blue LED 1 piece<br />
Photosynthesis Always<br />
LED<br />
UV LED<br />
Blue LED<br />
After water is supplied, and full ice is detected; When the<br />
door of refrigeration compartment, ice making compartment,<br />
or freezer compartment is open. (5 minutes maximum)<br />
Means Check with the diode range( ) of tester. (Use a<br />
tester equipped with diode range.)<br />
Photosynthesis<br />
LED<br />
UV LED<br />
Blue LED<br />
LEDs light in following<br />
colors at the above timing.<br />
Photosynthesis LED: Orange<br />
UV LED: Bluish white<br />
Blue LED: Blue<br />
The pointer of the tester does not shake when measuring<br />
between 4-pin connector No.1 (-) and No.2 (+). Make<br />
sure the pointer of the tester does not shake even if the<br />
polarities are reversed. Resistance: Short-circuited (0Ω)<br />
The pointer of the tester does not shake when measuring<br />
between 4-pin connector No.3 (+) and No.4 (-). Make<br />
sure the pointer of the tester does not shake even if the<br />
polarities are reversed. Resistance: Short-circuited (0 )<br />
Note: LED cannot be replaced<br />
individually because it<br />
is combined with the<br />
fan grille and partition<br />
V/F.<br />
Use a tester equipped<br />
with a diode range<br />
39<br />
UV/Blue<br />
Photosynthesis<br />
LED<br />
4 3 2 1<br />
Photosynthesis<br />
UV LED<br />
AC 230V<br />
Blue LED<br />
Parts Mounted<br />
Position<br />
On the external<br />
surface of the<br />
tank holder<br />
On the ceiling<br />
vegetable compartment<br />
(Vegetable<br />
compartment<br />
LED board)