Components/<br />

Part Name<br />

LED for bacteria<br />

removal from<br />

water tank<br />

(12V DC)<br />

Vegetable compartmentphotosynthesis,<br />

UV<br />

LED, Blue LED<br />

(12V DC)<br />

Check Method and Criterion<br />

6-7 TEST POINT DIAGRAM OF FILTER BOARD<br />

<strong>MR</strong>-<strong>G57N</strong>-<strong>NZ</strong><br />

AC 230V<br />

Timing in<br />

making contact<br />

Abnormal<br />

condition<br />

LED<br />

Timing in<br />

making contact<br />

Abnormal<br />

condition<br />

•After water is supplied to the ice tray.<br />

•After the ice level sensor lever detects that ice storage<br />

becomes full.<br />

•While the door is kept open for maximum of 5 minutes.<br />

When the door is opened, LED goes out within 5 minutes.<br />

Make sure if the connector is securely connected.<br />

Note: LED cannot be replaced individually because<br />

it is embedded in the tank holder.<br />

Photosynthesis LED 3 pieces + UV LED 1 piece + Blue LED 1 piece<br />

Photosynthesis Always<br />

LED<br />

UV LED<br />

Blue LED<br />

After water is supplied, and full ice is detected; When the<br />

door of refrigeration compartment, ice making compartment,<br />

or freezer compartment is open. (5 minutes maximum)<br />

Means Check with the diode range( ) of tester. (Use a<br />

tester equipped with diode range.)<br />

Photosynthesis<br />

LED<br />

UV LED<br />

Blue LED<br />

LEDs light in following<br />

colors at the above timing.<br />

Photosynthesis LED: Orange<br />

UV LED: Bluish white<br />

Blue LED: Blue<br />

The pointer of the tester does not shake when measuring<br />

between 4-pin connector No.1 (-) and No.2 (+). Make<br />

sure the pointer of the tester does not shake even if the<br />

polarities are reversed. Resistance: Short-circuited (0Ω)<br />

The pointer of the tester does not shake when measuring<br />

between 4-pin connector No.3 (+) and No.4 (-). Make<br />

sure the pointer of the tester does not shake even if the<br />

polarities are reversed. Resistance: Short-circuited (0 )<br />

Note: LED cannot be replaced<br />

individually because it<br />

is combined with the<br />

fan grille and partition<br />

V/F.<br />

Use a tester equipped<br />

with a diode range<br />

39<br />

UV/Blue<br />

Photosynthesis<br />

LED<br />

4 3 2 1<br />

Photosynthesis<br />

UV LED<br />

AC 230V<br />

Blue LED<br />

Parts Mounted<br />

Position<br />

On the external<br />

surface of the<br />

tank holder<br />

On the ceiling<br />

vegetable compartment<br />

(Vegetable<br />

compartment<br />

LED board)