SEC-400series - Shavo Technologies
SEC-400series - Shavo Technologies
SEC-400series - Shavo Technologies
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>SEC</strong>-8000/2000 series<br />
<strong>SEC</strong>-<br />
SEF-<br />
mass flow ( controller )<br />
Model<br />
mass flow ( meter )<br />
Materials used in gas contact area<br />
Valve type<br />
Standard flow rate range<br />
(N2 equivalent F.S.)<br />
Flow rate control range<br />
Response speed<br />
Accuracy<br />
Linearity<br />
Repeatability<br />
Operating differential pressure *1<br />
Maximum operating pressure<br />
Pressure Resistance<br />
Leak Integrity<br />
Operating temperature<br />
Flow rate setting signal<br />
Flow rate output signal<br />
Drive power source<br />
8340S<br />
8340S<br />
5/10/20/50/<br />
100200/500 SCCM<br />
1/2 SLM<br />
50 to 300 kPa (d)<br />
8440S<br />
8440S<br />
8450S<br />
8450S<br />
3/5/10 SLM<br />
Less than 2 sec (T98)<br />
100 to 300 kPa (d)<br />
8455S<br />
8455S<br />
10/20 SLM<br />
L type: 80 to 100°C; M type: 100 to 120°C<br />
8460S<br />
8460S<br />
Open at power-off: O<br />
± 1% F.S.<br />
± 0.5% F.S.<br />
± 0.2% F.S.<br />
300 kPa (G)<br />
1 MPa (G)<br />
0 to 5VDC (Minimun load resistance 2kΩ)<br />
1/4 VCR type<br />
3/8 VCR type<br />
1/4 VCR type<br />
3/8 VCR type<br />
*1 The operating pressure may vary depending on the conditions of use. Please contact HORIBA STEC about this. The <strong>SEC</strong>-8340 type features a heater within the main unit.<br />
* SCCM and SLM are symbols indicating gas flow rate (mL/min, L/min at 0°C, 101.3 kPa).<br />
* Viton ® Standard Fitting<br />
is registered trademark of E. I. DuPont de Nemours.<br />
<strong>SEC</strong>-400 series<br />
mass flow<br />
<strong>SEC</strong>- ( controller )<br />
Model<br />
mass flow<br />
SEF- ( meter )<br />
Materials used in gas contact area<br />
Valve type<br />
Standard flow rate range<br />
(N2 equivalent F.S.) *1<br />
Flow rate control range<br />
Response speed<br />
Accuracy<br />
Linearity<br />
Repeatability<br />
Operating differential pressure<br />
(for <strong>SEC</strong> series)<br />
310<br />
310<br />
Open at power-off: O<br />
Close at power-off: C<br />
± 1% F.S.<br />
± 0.5% F.S.<br />
± 0.2% F.S.<br />
5/10/20/30/50/<br />
100200/500 SCCM<br />
2 to 100% F.S.<br />
320<br />
320<br />
± 2% F.S.<br />
± 1% F.S.<br />
± 0.4% F.S.<br />
SUS316L<br />
20/30/<br />
50 SLM<br />
2 to 100% F.S.<br />
20/30 SLM<br />
100 to 300 kPa (d)<br />
50 SLM<br />
150 to 300 kPa (d)<br />
5 x 10 -12 Pa·m 3 /s (He)<br />
8440LS<br />
8440LS<br />
5/10/20/30<br />
50/100/200<br />
300/500 SCCM<br />
1/2/3/5 SLM<br />
50 to 300<br />
kPa (d)<br />
0.1 to 5VDC (Input impedance : more then 1MΩ)<br />
+15 VDC ± 5%, 60 mA; -15 VDC ± 5%, 60 mA, 1.8 VA<br />
<strong>SEC</strong>-8340S: For heater, AC 100 V, 56 VA<br />
Open at power-off: O<br />
0.1 to 5VDC (Input impedance : more then 1MΩ)<br />
*1 Compatible with the following gases: N2, Ar, H2, O2, CO2, CH4, C3H8<br />
* SCCM and SLM are symbols indicating gas flow rate (mL/min, L/min at 0°C, 101.3 kPa).<br />
* Viton ® Maximum operating pressure<br />
Pressure Resistance<br />
Leak Integrity<br />
Operating temperature<br />
Flow rate setting signal<br />
Flow rate output signal<br />
Drive power source<br />
Standard Fitting<br />
is registered trademark of E. I. DuPont de Nemours.<br />
<strong>SEC</strong>-<br />
SEF-<br />
mass flow ( controller )<br />
Model<br />
mass flow ( meter )<br />
Materials at gas contact area<br />
Valve type<br />
Standard flow rate range<br />
(N2 equivalent F.S.)<br />
Flow rate control range<br />
Response speed<br />
Accuracy<br />
Linearity<br />
Repeatability<br />
Operating differential pressure<br />
(for <strong>SEC</strong> series)<br />
Maximum operating pressure<br />
Pressure Resistance<br />
Leak Integrity<br />
Operating temperature<br />
Flow rate setting signal<br />
Flow rate output signal<br />
551<br />
551<br />
Open at power-off: O<br />
Close at power-off: C<br />
± 1% F.S.<br />
± 0.5% F.S.<br />
± 0.2% F.S.<br />
30/50/100 SLM<br />
5 to 100% F.S.<br />
552<br />
552<br />
0.25 to 5VDC (Input impedance : more then 1MΩ)<br />
610<br />
610<br />
405<br />
405<br />
± 0.5% F.S.<br />
± 0.5% F.S.<br />
± 0.2% F.S.<br />
50 to 300kPa (d)<br />
50/100/150 SLM<br />
10/20/30/50/100/<br />
200/300/500 SCCM<br />
1/2/3/5 SLM<br />
± 2% F.S.<br />
± 1% F.S.<br />
± 2% F.S.<br />
± 1% F.S.<br />
± 0.5% F.S.<br />
± 1% F.S.<br />
± 0.4% F.S. ± 0.2% F.S. ± 0.4% F.S.<br />
50 to 300 kPa (d) (Pressure may be limited with some gas types and flow rates.)<br />
+15 VDC ± 5%, 60 mA; -15 VDC ± 5%, 150 mA, 3.2 VA<br />
3/8 Swagelok type<br />
* The <strong>SEC</strong>-400MK3 and <strong>SEC</strong>-500MK3 are compatible with the following gases: Air, N2, O2, Ar, H2, He<br />
* SCCM and SLM are symbols indicating gas flow rate (mL/min, L/min at 0°C, 101.3 kPa).<br />
* Viton ® Drive power source<br />
Standard Fitting<br />
is registered trademark of E. I. DuPont de Nemours.<br />
8450LS<br />
8450LS<br />
10/20 SLM<br />
Less than 1 sec (T98)<br />
100 to 300<br />
kPa (d)<br />
8455LS<br />
8455LS<br />
30/50 SLM<br />
30 SLM 50 SLM<br />
100 to 300 kPa (d) 100 to 300 kPa (d)<br />
50 SLM 100 SLM<br />
150 to 300 kPa (d) 150 to 300 kPa (d)<br />
L type: 15 to 35°C; M type: 35 to 60°C; H type: 60 to 80°C<br />
410<br />
410<br />
SUS316, Viton ®<br />
Less than 6 sec (T98)<br />
300 kPa (G)<br />
1 MPa (G)<br />
1 x 10-8 Pa·m3 /s (He)<br />
5 to 50°C (accuracy guaranteed between 15 and 35°C)<br />
0 to 5VDC (Minimun load resistance 2kΩ)<br />
+15 VDC ± 5%, 60 mA; -15 VDC ± 5%, 150 mA, 3.15 VA<br />
1/4 Swagelok type<br />
620<br />
620<br />
10 to 100% F.S.<br />
SUS316, Viton ®<br />
150/200 SLM<br />
(H2:300 SLM)<br />
Less than 6 sec (T98)<br />
± 0.5% F.S.<br />
300 kPa (G)<br />
1 MPa (G)<br />
1 x 10-8 Pa·m3 /s (He)<br />
5 to 50°C (accuracy guaranteed between 15 and 35°C)<br />
0.5 to 5VDC (Input impedance : more then 1MΩ)<br />
623<br />
623<br />
0 to 5VDC (Minimun load resistance 2kΩ)<br />
510<br />
510<br />
10/20 SLM<br />
5 to 100% F.S.<br />
± 1% F.S.<br />
± 0.2% F.S.<br />
8460LS<br />
8460LS<br />
50/100 SLM<br />
0.25 to 5VDC (Input impedance : more then 1MΩ)<br />
Open at power-off: O<br />
400MK2<br />
——<br />
10/20/30/50/100<br />
200/300/500 SCCM<br />
1/2/3/5 SLM<br />
2410<br />
2410<br />
10/20/30/50/<br />
100/200/300/<br />
500 SCCM<br />
1/2/3/5 SLM<br />
Open at power-off: O Close at power-off: C<br />
± 0.5% F.S.<br />
500MK2<br />
——<br />
10/20 SLM<br />
± 2% F.S.<br />
± 1% F.S.<br />
50 to 300 kPa (d)<br />
1/4 VCR type<br />
2510<br />
2510<br />
SUS316L, Viton ®<br />
10/20 SLM<br />
5 to 100% F.S.<br />
Less than 6 sec (T98)<br />
2551<br />
2551<br />
30/50/<br />
100 SLM<br />
100 to 300<br />
kPa (d)<br />
1 x 10-8 Pa·m3 /s (He)<br />
Specify between 35 and 80°C.<br />
0.25 to 5VDC (Input impedance : more then 1MΩ)<br />
+15 VDC ± 5%, 60 mA; -15 VDC ± 5%, 150 mA, 3.2 VA<br />
510A<br />
510A<br />
5 to 100% F.S.<br />
± 0.2% F.S.<br />
50 to 300kPa (d)<br />
30/50 SLM<br />
100 to 300kPa (d)<br />
400MK3<br />
——<br />
10/20/30/50/100<br />
200/300/500 SCCM<br />
1/2/3/5 SLM<br />
0.25 to 5VDC (Input impedance : more then 1MΩ)<br />
+15 VDC ± 5%, 60 mA; -15 VDC ± 5%, 150 mA, 3.15 VA<br />
1/4 Swagelok type<br />
Mass Flow Controllers 20<br />
520A<br />
520A<br />
± 2% F.S.<br />
± 0.4% F.S.<br />
3/8 VCR type<br />
500MK3<br />
——<br />
10/20 SLM