Type E METRIC / Typ E METRISCH / Type E METRIQUE / Tipo E MÉTRICO /<br />
Tipo E METRICO<br />
METRIC TYPE E TAPERED ROLLER BEARINGS / METRISCHER TYP E KEGELROLLENLAGER /<br />
ROULEMENTS A ROULEAUX CONIQUES DE TYPE E METRIQUE / RODAMIENTOS DE RODILLOS<br />
CÓNICOS DE TIPO E MÉTRICO / TIPO- E METRICO E CUSCINETTI A RULLI CONICI<br />
Ball Bearing<br />
DODGE Type E Double Row Tapered Roller Bearings<br />
have the capacity to carry heavy radial loads, thrust<br />
loads and <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>bined radial and thrust loads. The<br />
maximum re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended load which can be applied<br />
is limited by various <s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>ponents in the system such<br />
as bearing, housing, shaft, shaft attachment, speed<br />
and life requirements as listed in this catalog. DODGE<br />
Unitized Type E Roller Bearings have been applied<br />
successfully even when these limits have been<br />
exceeded under con<strong>tr</strong>olled operating conditions.<br />
L 10<br />
Life, Hours -- The life which may be expected from<br />
at least 90% of a given group of bearings operating<br />
under identical conditions.<br />
L 10<br />
Life, Hours =<br />
Where:<br />
10/3<br />
1,500,000<br />
( ) X<br />
C 90<br />
P<br />
RPM<br />
C 90<br />
= Dynamic Capacity (Table 1), kN<br />
P = Equivalent Radial Load, kN<br />
(See Equation 1 On Page B5-15 for definition<br />
of P)<br />
GENERAL<br />
Heavy Service -- For heavy shock loads, frequent<br />
shock loads, or severe vibrations, increase the<br />
Equivalent Radial Load by up to 50% (according to<br />
severity of conditions) to obtain a Modified Equivalent<br />
Radial Load. Consult Application Engineering at 864-<br />
284-5700 for additional selection assistance.<br />
Thrust load values shown in the table are<br />
re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended as a guide for general applications<br />
that will give adequate L 10<br />
life for plummer blocks.<br />
The maximum thrust load should not exceed values<br />
shown on Table 1. Where substantial radial load is<br />
also present, it is advisable to calculate actual L 10<br />
life to assure that it meets the requirements. The<br />
effectiveness of the shaft attachment to carry thrust<br />
load depends on proper tightening of the setscrews,<br />
shaft tolerance and shaft deflections. Therefore, it is<br />
advisable to use auxiliary thrust carrying devices such<br />
as shaft shoulder, snap ring or a thrust collar to locate<br />
the bearing under thrust loads heavier than shown<br />
below, or where ex<strong>tr</strong>eme reliability is <s<strong>tr</strong>ong>des</s<strong>tr</strong>ong>ired.<br />
RPM RANGE<br />
RPM-BEREICH<br />
GAMME DES VITESSES DE<br />
ROTATION<br />
20-200 201-2000 over 2000<br />
INTERVALO RPM<br />
RECOMMENDED THRUST LOAD<br />
RECOMMENDED THRUST LOAD C 90<br />
/4 C 90<br />
/8 C 90<br />
/12<br />
EMPFOHLENE AXIALLAST C 90<br />
/4 C 90<br />
/8 C 90<br />
/12<br />
POUSSEE AXIALE<br />
RECOMMANDEE<br />
C 90<br />
/4 C 90<br />
/8 C 90<br />
/12<br />
CARGA AXIAL RECOMENDADA C 90<br />
/4 C 90<br />
/8 C 90<br />
/12<br />
CARICO ASSIALE<br />
RACCOMANDATO<br />
C 90<br />
/4 C 90<br />
/8 C 90<br />
/12<br />
The shaft tolerances re<s<strong>tr</strong>ong>com</s<strong>tr</strong>ong>mended below are<br />
adequate for the conditions outlined in this catalog.<br />
Since the allowable load, especially at a low speed,<br />
is very large, the shaft should be checked to assure<br />
adequate shaft s<strong>tr</strong>ength.<br />
The magnitude and direction of both the thrust and<br />
radial load must be taken into account when selecting<br />
a shaft size. Heavy loads should be directed through<br />
the base. Where uplift loads are involved see Table<br />
4, page B5B5-24 for maximum values. Where a load<br />
pulls the housing away from the mounting base, both<br />
the hold-down bolts and housing must be of adequate<br />
s<strong>tr</strong>ength. Auxiliary load carrying devices such as shear<br />
bars are advisable for side or end loading of plummer<br />
blocks.<br />
SHAFT TOLERANCES / WELLENTOLERANZEN /<br />
TOLERANCES D’ARBRE / TOLERANCIAS DEL EJE /<br />
TOLLERANZE DELL’ALBERO<br />
SHAFT SIZE<br />
TOLERANCE<br />
WELLENGRÖSSE<br />
TOLERANZ<br />
DIMENSIONS DE L’ARBRE<br />
TOLERANCE<br />
TAMAÑO DEL EJE<br />
TOLERANCIA<br />
DIMENSIONI DELL’ALBERO TOLLERANZA<br />
Up to 35mm<br />
+.000 - .013mm<br />
40 to 100mm +.000 - .025mm<br />
100 - 150mm +.000 - .038mm<br />
160 - 180mm +.000 - .051mm<br />
Type E<br />
Two-Bearing Housings<br />
SOLIDLUBE<br />
E-Z KLEEN<br />
B5-9