10.07.2015 Views

ZOLarium 23 - Ziekenhuis Oost-Limburg

ZOLarium 23 - Ziekenhuis Oost-Limburg

ZOLarium 23 - Ziekenhuis Oost-Limburg

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BILLBOARDProgrammaWetenschappelijke Raad- Wanneer zuigelingen ontroostbaar huilen(donderdag 15 februari 2007). Aula ZOL,20.30 uur. Rubriek 2-20 NE.- Acute traumatologie in de huisartsenpraktijk(donderdag 15 maart 2007). Aula ZOL,20.30 uur. Rubriek 2-20 NE.- Het ge(mis)bruik van het medische attest(donderdag 24 mei 2007). Aula ZOL, 20.30uur. Rubriek 6-20 NE.- Evidence based medicine richtlijnen omtrentdiagnostiek en behandeling van lage rugpijn.Welke zijn de chirurgische en interventionelebehandelingsmogelijkheden. (donderdag24 mei 2007). Aula ZOL, 20 uur. Rubriek2-30 NE.- Rationeel antibioticagebruik in de ambulantepraktijk. (donderdag 21 juni 2007).Aula ZOL, 20.30 uur. Rubriek 6-20 NE.Meer info: www.zol.beCONGRESSEN• Thorazol: Congres Thoraxcentrum 2007, vrijdag2 maart 2007 in Landcommanderij AldenBiesen. Meer info: PM.secretariaat@zol.be ofop www.zol.be• Epsoma: Multidisciplinaritis: wie helpt?’ Overde psychosociale zorg in een algemeen ziekenhuis,op 27 april 2007 in LandcommanderijAlden Biesen.Info: E-mail: Marie-Louise.Heymans@zol.beof op www.zol.bePOSTERTitle: Inappropriate Mode Switch in IECD!|sdue to Far-Field R Sensing. Analysis usingthe saved IECG’sAuthors: Philip De Vusser , Ch. VanKerrebroekAccepted for: Cardiorhythm 2007, 2-4 February2007, Hong KongBackground: Little has been published on Far-Field R signals in ICD!sMethods: We screened device-saved IECG!s tolook for the presence of Far-Fieled R signals. Ina total of 20 patients we retrieved 72 IECG!s.Only 5 IECG!s (6,4%) documented ventricularpaced events.We defined Far-Field R any signal on the atrialchannel with peak to peak amplitude of at least0,2mV with onset falling within –50ms and +100ms from the Ventricular Event Marker.Results: In 75% of the IECG!S Far-Field R was documented,all after ventricular sense. The mean Far-Field R amplitude was 0,61 mV with a STDDEV of0,39mV. Ventric. event to Far-Field R onset variedfrom –50 to + 90 ms. Only 6 IECG!s showed a positiveFar-Field R onset. Far-Field R signal durationvaried from 40 to 140 ms. 26% of the Far-FieldR signals have been seen at least intermittentlyby the device. In 9 (4 patients) of these 14 situationsthis led to inappropriate mode switches.Programming the Far-R suppression algorithm!§ON!.. with appropriate duration resolved theinappropriate mode switches.Conclusions: 1. In 75% of the IECG!s Far-FieldR was documented. Only 26% of these were atleast intermittently seen by the device. In 17%of the situations inappropriate mode switcheswere documented.2. Programming the Far-R suppression algorithm!§ON!.. with an appropriate duration eliminatedinappropriate mode switches.39

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!