GB USER INSTRUCTIONS <strong>Cooler</strong> <strong>and</strong> <strong>Freezer</strong><br />
Switch-off voltage High Med Low<br />
12 V operation 11.3 V 10.8 V 10.0 V<br />
24 V operation 24.6 V 23.6 V 22.0 V<br />
Switch-on voltage<br />
12 V operation 12.5 V 12.0 V 11.3 V<br />
24 V operation 26.0 V 25.0 V 23.4 V<br />
It is absolutely necessary to disconnect the cooler from the battery when a high-rate charger is being used.<br />
When used in a tip-up truck cab, switch off the cooler before tipping the cab forward.<br />
Useful advice:<br />
Foodstuffs <strong>and</strong> beverages stored in the cooler should always be in closed containers or wrapped so that air can circulate around these<br />
refrigerated items. Do not place warm or hot foods or beverages into the cooler.<br />
6. Maintenance <strong>and</strong> storage<br />
A heavy build-up of frost <strong>and</strong> ice in the unit will reduce its cooling effect. Do not use sharp objects to remove the layer of frost <strong>and</strong><br />
ice; instead, switch off the unit <strong>and</strong> allow it to defrost. It is recommended that the unit be regularly defrosted.<br />
If the unit is not in use over an extended period of time, open the lid enough to produce an air gap so that fresh air can circulate in<br />
the cool-space.<br />
Important notice:<br />
Maintenance or repair work, particularly on the cooling aggregate, cooling circuit or electronics, may only be performed by qualified<br />
technicians.<br />
Troubleshooting notice:<br />
Before you call customer service with a problem, we recommend that you check the following aspects:<br />
• Is the unit in a suitable location where it has adequate ventilation?<br />
• Does the outlet where the unit is connected have power?<br />
• Is the connecting cable damaged?<br />
• Is the plug fully inserted into the outlet?<br />
• Is the unit switched on?<br />
The unit has its own fault diagnostic system that helps to find the source of problems. Watch the LED next to the on/off<br />
button:<br />
1 blink: the input voltage is too low<br />
2 blinks: ventilator current is too high<br />
3 blinks: compressor start-up fault, locked rotor<br />
4 blinks: compressor speed fault, the cooling system is overloaded<br />
5 blinks: compressor over-temperature shutdown<br />
If the LED indicates faults 3, 4 or 5, empty the cooler put it in a cool location <strong>and</strong> then try to start it again.<br />
If “Er” appears in the temperature display, the temperature sensor may be faulty. This unit has an emergency-operation system for this<br />
case. This will maintain a minimum level of cooling. The temperature cannot be precisely regulated under these conditions.<br />
If these checks do not lead to flawless operation of the unit then please contact customer service.<br />
7. Releasing the lid's hinge (only models 25, 35, 45)<br />
If the cooler is to be used in a confined space where raising its lid is difficult, you can release the lid hinge to make the lid<br />
removable.<br />
Loosen the lid latch with a screwdriver as shown in the illustration (later picture). Once this has<br />
been done, the lid need only be open to an angle of about 20° to remove or replace it.<br />