02.10.2014 Views

Bedienungsanleitung EZetil® Compressor Cooler and Freezer - ELV

Bedienungsanleitung EZetil® Compressor Cooler and Freezer - ELV

Bedienungsanleitung EZetil® Compressor Cooler and Freezer - ELV

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

GB USER INSTRUCTIONS <strong>Cooler</strong> <strong>and</strong> <strong>Freezer</strong><br />

Switch-off voltage High Med Low<br />

12 V operation 11.3 V 10.8 V 10.0 V<br />

24 V operation 24.6 V 23.6 V 22.0 V<br />

Switch-on voltage<br />

12 V operation 12.5 V 12.0 V 11.3 V<br />

24 V operation 26.0 V 25.0 V 23.4 V<br />

It is absolutely necessary to disconnect the cooler from the battery when a high-rate charger is being used.<br />

When used in a tip-up truck cab, switch off the cooler before tipping the cab forward.<br />

Useful advice:<br />

Foodstuffs <strong>and</strong> beverages stored in the cooler should always be in closed containers or wrapped so that air can circulate around these<br />

refrigerated items. Do not place warm or hot foods or beverages into the cooler.<br />

6. Maintenance <strong>and</strong> storage<br />

A heavy build-up of frost <strong>and</strong> ice in the unit will reduce its cooling effect. Do not use sharp objects to remove the layer of frost <strong>and</strong><br />

ice; instead, switch off the unit <strong>and</strong> allow it to defrost. It is recommended that the unit be regularly defrosted.<br />

If the unit is not in use over an extended period of time, open the lid enough to produce an air gap so that fresh air can circulate in<br />

the cool-space.<br />

Important notice:<br />

Maintenance or repair work, particularly on the cooling aggregate, cooling circuit or electronics, may only be performed by qualified<br />

technicians.<br />

Troubleshooting notice:<br />

Before you call customer service with a problem, we recommend that you check the following aspects:<br />

• Is the unit in a suitable location where it has adequate ventilation?<br />

• Does the outlet where the unit is connected have power?<br />

• Is the connecting cable damaged?<br />

• Is the plug fully inserted into the outlet?<br />

• Is the unit switched on?<br />

The unit has its own fault diagnostic system that helps to find the source of problems. Watch the LED next to the on/off<br />

button:<br />

1 blink: the input voltage is too low<br />

2 blinks: ventilator current is too high<br />

3 blinks: compressor start-up fault, locked rotor<br />

4 blinks: compressor speed fault, the cooling system is overloaded<br />

5 blinks: compressor over-temperature shutdown<br />

If the LED indicates faults 3, 4 or 5, empty the cooler put it in a cool location <strong>and</strong> then try to start it again.<br />

If “Er” appears in the temperature display, the temperature sensor may be faulty. This unit has an emergency-operation system for this<br />

case. This will maintain a minimum level of cooling. The temperature cannot be precisely regulated under these conditions.<br />

If these checks do not lead to flawless operation of the unit then please contact customer service.<br />

7. Releasing the lid's hinge (only models 25, 35, 45)<br />

If the cooler is to be used in a confined space where raising its lid is difficult, you can release the lid hinge to make the lid<br />

removable.<br />

Loosen the lid latch with a screwdriver as shown in the illustration (later picture). Once this has<br />

been done, the lid need only be open to an angle of about 20° to remove or replace it.<br />

– 8 –<br />

18265_EZetil_KompressorBedienAra8 8 10.03.2008 9:30:19 Uhr

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!