7.1 Coolant filling<br />

Prior to <strong>start</strong>ing the SET Camino Generator<br />

Fill cooler:<br />

1. Unscrew plug at expansion vessel.<br />

Camino Generator<br />

2. Fill coolant in the expansion vessel until coolant becomes visible.<br />

3. Bleed at the water-cooled exhaust gas elbow (1) at the system bleeding screw<br />

(2).<br />

4. Tighten plug.<br />

5. If necessary, bleed the cooling circuits directly downstream of the pumps.<br />

After <strong>start</strong>ing<br />

1. Start the SET Camino Generator.<br />

2. Top <strong>up</strong> coolant in the expansion vessel.<br />

3. Check the cooler ventilator for proper operation.<br />

If the fist <strong>start</strong> was not successful, turn control panel to „OFF“ <strong>and</strong> wait for approx. 5<br />

s.<br />

Then <strong>start</strong> again.<br />

Look for leaks (re-tighten hose clips).<br />

1. Water-cooled exhaust gas elbow<br />

2. Bleeding screw<br />

03-04-01 Initial <strong>start</strong>-<strong>up</strong> 7-54<br />

2<br />

1