Measuring system with <strong>VEGAPULS</strong> <strong>54K</strong> via separator (Smart-Transmitter)<br />

on passive PLC<br />

Two-wire technology (loop powered), intrinsically safe ia supply via the signal cable of the<br />

separator for operation of the sensor in Ex zone 1<br />

Output signal sensor 4 … 20 mA passive.<br />

Output signal separator 4 … 20 mA active<br />

Optional external indicating instrument with analogue and digital display (can be mounted<br />

up to 25 m away from the sensor).<br />

Adjustment with PC, HART ® handheld or adjustment module MINICOM (can be plugged into<br />

the sensor or into the external indicating instrument VEGADIS 50).<br />

VEGADIS 50<br />

4<br />

Zone 0<br />

or<br />

Zone 1<br />

Ex area Non Ex area<br />

EEx ia<br />

Separator (e.g. VEGATRENN 149 Ex see<br />

"3.2 Approvals“)<br />

2<br />

2<br />

2<br />

VEGA-<br />

CONNECT 2<br />

1) If the resistance of the processing systems<br />

connected to the 4 … 20 mA signal output is less<br />

than 200 Ω, a resistor must be connected to the<br />

connection cable during adjustment to get a loop<br />

resistance of 250 Ω up to 350 Ω.<br />

The digital adjustment signal would otherwise be<br />

severely damped or short-circuited due to<br />

insufficient resistance of the connected processing<br />

system. Digital communication with the PC<br />

would not be ensured.<br />

1)<br />

4 … 20 mA<br />

(active) 2)<br />

24 <strong>VEGAPULS</strong> <strong>54K</strong> <strong>enamel</strong><br />

+<br />

-<br />

PLC (passive) 3)<br />

HART ® handheld<br />

Electrical connection<br />

2) 4 … 20 mA active means that the separator<br />

delivers a level-dependent current of 4 … 20 mA<br />

The separator reacts electrically to the PLC like a<br />

current source.<br />

3) 4 … 20 mA passive means that the PLC consumes<br />

a level-dependent current of 4 … 20 mA. The PLC<br />

reacts electrically like a varying resistor (consumer).<br />