24 101-EN-041227<br />

Technical data<br />

6 Technical data<br />

6.1 Technical data<br />

Power supply<br />

Power supply<br />

- four-wire sensor 24 V DC (20 … 72 V DC)<br />

230 V AC (20 … 250 V AC), 50/60 Hz<br />

fuse 0.2 A TR<br />

- two-wire sensor 24 V DC (14 … 36 V DC)<br />

- two-wire Ex ia sensor 24 V DC (14 … 29 V DC)<br />

- two-wire Ex d ia sensor 24 V DC (20 … 36 V DC)<br />

Current consumption<br />

- four-wire sensor max. 60 mA<br />

- two-wire sensor max. 22.5 mA<br />

Power consumption<br />

- four-wire sensor max. 200 mW, 1.2 VA<br />

- two-wire sensor 55 … 810 mW<br />

Load<br />

- four-wire sensors max. 500 Ohm<br />

- two-wire sensors see load diagram<br />

Ω<br />

1000<br />

975<br />

900<br />

800<br />

720<br />

700<br />

670<br />

600<br />

500<br />

400<br />

max. load Ex ia<br />

max. load non-Ex<br />

max. load Ex d ia<br />

Non-Ex and Ex ia<br />

max. voltage limit<br />

non-Ex and<br />

Ex d ia sensors<br />

max. Spannungsgrenze<br />

Ex ia-Sensoren<br />

300<br />

250<br />

200<br />

Load resistance<br />

(HART<br />

100<br />

0<br />

15 19,5<br />

25,5 29 36<br />

14 20 25 30 35<br />

® min. voltage limit when using the HART<br />

and<br />

VEGACONNECT)<br />

®<br />

adjustment resistance:<br />

- non-Ex and Ex ia sensors<br />

- Ex d ia sensors<br />

Exd ia<br />

<strong>VEGAPULS</strong> <strong>54K</strong> <strong>enamel</strong> 39<br />