1/29/98 102 C95.3-1991 Revision — 2 nd Draft<br />

10/98 Draft<br />

V = RMS voltage on each line with respect to the neutral plane midway between the<br />

wires (V)<br />

Z 0 = Characteristic impedance of the transmission line (Ω)<br />

= 120 cosh -1 (d/r)<br />

d = Distance from the field point P (midpoint of line) to the center of each wire (m)<br />

r = Radius of each wire (m)<br />

Fig A3 Parallel Wire Transmission Line <strong>for</strong> Generating E- <strong>and</strong> H-Fields<br />

Copyright © 1998 IEEE. All rights reserved. This is an unapproved IEEE St<strong>and</strong>ards Draft,<br />

subject to change.