31.12.2013 Views

DRAFT Recommended Practice for Measurements and ...

DRAFT Recommended Practice for Measurements and ...

DRAFT Recommended Practice for Measurements and ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1/29/98 132 C95.3-1991 Revision — 2 nd Draft<br />

10/98 Draft<br />

[ ] Furse, C. M. <strong>and</strong> G<strong>and</strong>hi, O. P. “Validation of the FDTD Method <strong>for</strong> Canonical<br />

Problems with Near-Field Sources,” Interim Report No. 1, Oct. 1995, (Submitted to<br />

Wireless Technology Research, L. L. C, Washington, DC 20036)<br />

[ ] Furse, C. M., Mathur, S. P. <strong>and</strong> G<strong>and</strong>hi, O. P., “Improvements in the Finite-Difference<br />

Time-Domain Method <strong>for</strong> Calculating the Radar Cross Section of a Perfectly Conducting<br />

Target,” IEEE Transactions on Microwave Theory <strong>and</strong> Techniques, vol. MTT-38, no. 7,<br />

pp. 919 - 927, 1990.<br />

[ ] Gabriel, C., “Compilation of the Dielectric Properties of Body Tissues at RF <strong>and</strong><br />

Microwave Frequencies,” Final technical Report, Occupational <strong>and</strong> Environmental Health<br />

Directorate, RFR Division, Brooks AF Base, TX 78235-5102, AL/OE-TR-1996-0037, June<br />

1996.<br />

[ ] G<strong>and</strong>hi, O. P., “Numerical Methods <strong>for</strong> Specific Absorption rate Calculations,”<br />

Chapter 6 in Biological Effects <strong>and</strong> Medical Applications of Electromagnetic Energy, O.P.<br />

G<strong>and</strong>hi Ed., pp. 113 - 140, Prentice Hall, Englewood Cliffs, New Jersey, 1990.<br />

[ ] G<strong>and</strong>hi, O. P., “Some Numerical Methods <strong>for</strong> Dosimetry: Extremely Low Frequencies<br />

to Microwave Frequencies,” Radio Science, vol. 30, pp.161 - 177, Jan./Feb., 1995<br />

[ ] G<strong>and</strong>hi, O. P. <strong>and</strong> Chen, J. Y., “Electromagnetic Absorption in the Human Head from<br />

Experimental 6 GHz H<strong>and</strong>-Held Transceivers,” IEEE Transactions on Electromagnetic<br />

Compatibility, vol. EMC-37, pp. 547 - 558, 1995.<br />

[ ] G<strong>and</strong>hi, O. P., Chen, J. Y., “ Numerical Dosimetry at Power-Line Frequencies using<br />

Anatomically Based Models,” Bioelectromagnetics Supplement, 1, pp. 43 - 60, 1992.<br />

[ ] G<strong>and</strong>hi, O. P., Chen, S. B., Yuan, X. <strong>and</strong> Chen, J. Y., “Dosimetry <strong>for</strong> Time-Varying<br />

Magnetic Fields in MR Imaging,” p. 16, Abstracts of the Sixteenth Annual Meeting of the<br />

Bioelectromagnetics Society, Copenhagen, Denmark, June 12 - 17, 1994.<br />

[ ] G<strong>and</strong>hi, O. P. <strong>and</strong> DeFord, J. F. “Calculation of EM Power Deposition <strong>for</strong> Operator<br />

Exposure to RF Induction Heaters,” IEEE Transactions on Electromagnetic<br />

Compatibility, vol. EMC-30, pp. 63 - 68, 1988.<br />

[ ] G<strong>and</strong>hi, O. P., DeFord, J. <strong>and</strong> Kanai, K., “Impedance Method <strong>for</strong> Calculation of Power<br />

Deposition Patterns in Magnetically Induced Hyperthermia, IEEE Transactions on<br />

Biomedical Engineering, vol. BME-31, pp. 644 - 651, 1984.<br />

[ ] G<strong>and</strong>hi, O. P. <strong>and</strong> Furse, C. M., “Millimeter-Resolution MRI-Based Models of the<br />

Human Body <strong>for</strong> electromagnetic Dosimetry from ELF to Microwave Frequencies,” Voxel<br />

Phantom Development, Proceedings of an International Workshop held at the National<br />

Radiological Protection Board, Chilton, UK, P. J. Dimbylow, Ed., 1995.<br />

Copyright © 1998 IEEE. All rights reserved. This is an unapproved IEEE St<strong>and</strong>ards Draft,<br />

subject to change.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!