1/29/98 109 C95.3-1991 Revision — 2 nd Draft<br />

10/98 Draft<br />

Appendix C<br />

Additional Techniques <strong>for</strong> SAR Measurement<br />

C1 . Thermography<br />

A method <strong>for</strong> rapid evaluation of the distribution of SAR throughout an entire planar<br />

surface of a biological object or a model that is composed of heterogeneous dielectric<br />

materials is described in [C3, C10 ]. The method involves the use of a thermographic<br />

camera <strong>for</strong> recording the rate of rise of temperature in a plane that bisects an entire<br />

model (phantom) or a cadaver of a biological subject under study. The temperature<br />

distribution be<strong>for</strong>e, <strong>and</strong> immediately after brief, high-power irradiation, is observed on the<br />

Copyright © 1998 IEEE. All rights reserved. This is an unapproved IEEE St<strong>and</strong>ards Draft,<br />

subject to change.