Appendix 116/132<br />

9.1.3 Extended Device Diagnostic ASCII<br />

In this section the task states <strong>for</strong> ASCII devices are described.<br />

9.1.3.1 ASCII Protocol<br />

Figure 71: ASCII Protocol<br />

Variable<br />

Task state<br />

Send telegrams<br />

Receive telegrams<br />

Send errors<br />

Receive errors<br />

Error bits (hex)<br />

Last error<br />

Table 68: ASCII Protocol<br />

Meaning<br />

Actual state of the protocol process:<br />

0 = not initialized<br />

1 = basic state<br />

2 = telegram sequence time expires<br />

3 = sending mode<br />

4 = receiving mode<br />

Number of faultless transmitted telegrams<br />

Number of faultless received telegrams<br />

Number of send tasks which got lost because of Syntax or<br />

transmission errors<br />

Number of errors which have occurred by receiving data<br />

Assigns every reported error to an error class and shows this<br />

by setting a bit. It is only displayed, if the error has executed<br />

in spite of repeat a telegram loss<br />

Number of the last reported error. It is only displayed, if the<br />

error has occurred in spite of repeat a telegram loss<br />

The description of the error numbers see on the DVD in the<br />

manual asc_pre.pdf<br />

<strong>SyCon</strong> | <strong>System</strong> <strong>Configurator</strong> <strong>for</strong> Ethernet and serial Protocols<br />

DOC040601OI04EN | Revision 4 | English | 2012-06 | Released | Public © Hilscher, 2004-2012