05.03.2014 Views

Use of Models and Facility-Level Data in Greenhouse Gas Inventories

Use of Models and Facility-Level Data in Greenhouse Gas Inventories

Use of Models and Facility-Level Data in Greenhouse Gas Inventories

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Use</strong> <strong>of</strong> <strong>Models</strong> <strong>and</strong> <strong>Facility</strong>-<strong>Level</strong> <strong>Data</strong> <strong>in</strong> <strong>Greenhouse</strong> <strong>Gas</strong> <strong>Inventories</strong><br />

if the sample was sufficiently large, representative <strong>and</strong> homogenous with<strong>in</strong> the sub-population then the reported EF data<br />

may be utilised for that segment <strong>of</strong> the <strong>in</strong>ventory.<br />

Start<br />

<strong>Facility</strong> <strong>Level</strong> Activity <strong>Data</strong><br />

Does the facility level data provide full<br />

coverage <strong>of</strong> the sector?<br />

YES<br />

<strong>Use</strong> <strong>Facility</strong> level data set <strong>in</strong><br />

national <strong>in</strong>ventory<br />

NO<br />

<strong>Use</strong> <strong>Facility</strong> data for portion covered<br />

<strong>Use</strong> output <strong>of</strong> EF decision tree for<br />

uncovered portion.<br />

Start<br />

<strong>Facility</strong> <strong>Level</strong> Emission Factors<br />

Can it be demonstrated that the<br />

coverage <strong>and</strong> sample size <strong>of</strong> the facility<br />

data sample is sufficient<br />

NO<br />

YES<br />

Is the sample unbiased?<br />

NO<br />

YES<br />

Does the facility data sample have an<br />

approximate normal distribution?<br />

YES<br />

Is the mean EF <strong>of</strong> the facility data<br />

significantly different to the method 1<br />

default EF?<br />

NO<br />

Can the sample be divided <strong>in</strong>to<br />

homogenous groups (e.g. technology<br />

type, region, coal bas<strong>in</strong>) such that bias<br />

is not present?<br />

YES<br />

Does the sub sample<br />

cover more than X% <strong>of</strong> the sub group<br />

population?<br />

YES<br />

NO<br />

NO<br />

Should a part <strong>of</strong> the data<br />

be applied to the <strong>in</strong>ventory? (Can the new<br />

data improve the old?)<br />

YES<br />

NO<br />

Do not use facility data directly <strong>in</strong><br />

<strong>in</strong>ventory but for QA/QC checks.<br />

YES<br />

NO<br />

Extrapolate sub group data to sub<br />

group residual.<br />

<strong>Use</strong> facility specific EF data.<br />

Apply IEF for facility data to<br />

uncovered portion <strong>of</strong> sector.<br />

Review <strong>in</strong> light <strong>of</strong> QA/QC plan.<br />

<strong>Use</strong> facility specific EF data.<br />

<strong>Use</strong> exist<strong>in</strong>g <strong>in</strong>ventory default EF<br />

for the uncovered portion.<br />

Apply an EF to the uncovered<br />

portion that ma<strong>in</strong>ta<strong>in</strong>s the<br />

previous IEF for the whole sector.<br />

IPCC Expert Meet<strong>in</strong>g Report 105 TFI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!