Panel feed-through modules for<br />

flat-ribbon cable connectors<br />

VARIOFACE panel feed-through modules<br />

DFLK... connect the flat-ribbon cable<br />

connectors in accordance with IEC 60603-<br />

13/DIN 41651 to the screw connection<br />

terminal blocks.<br />

These modules are suitable for mounting<br />

on a side panel with an appropriate housing<br />

cutout (see dimensioning table).<br />

The modules are provided with low <strong>and</strong><br />

high engagement catches to protect the flatribbon<br />

cable connector against being<br />

accidentally released.<br />

Notes:<br />

Type of housing:<br />

Polyamide PA non-reinforced, color: green.<br />

For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />

solid str<strong>and</strong>ed<br />

[mm 2 ] AWG<br />

Connection data<br />

Screw connection 0.2-4 0.2-2.5 24-12<br />

No. of<br />

Description<br />

pos.<br />

VARIOFACE feed-through module, with pin strip<br />

<strong>INTERFACE</strong> <strong>Cabling</strong><br />

VARIOFACE wiring interface<br />

DFLK<br />

Module width<br />

W Type Order No. Pcs. /<br />

Pkt.<br />

16 39.00 DFLK 16 2280239 5<br />

20 39.00 DFLK 20 2280242 5<br />

26 39.00 DFLK 26 2280255 5<br />

34 39.00 DFLK 34 2280268 5<br />

40 39.00 DFLK 40 2280271 5<br />

50 39.00 DFLK 50 2280284 5<br />

Technical data<br />

Operating voltage<br />

< 50 V AC / 60 V DC<br />

Max. perm. current (per branch)<br />

1 A<br />

Test voltage<br />

500 V (50 Hz, 1 min.)<br />

Ambient temperature range -20°C ... 45°C<br />

Mounting position<br />

Any<br />

St<strong>and</strong>ards/regulations IEC 60664, DIN EN 50178, IEC 62103<br />

Dimensioning of the housing cutout<br />

Dimensional drawing DFLK:<br />

b<br />

c +0,2<br />

39<br />

24,3<br />

d +0,2<br />

4<br />

49<br />

Type a b c d<br />

38<br />

DFLK 16 58.4 52.5 40.1 + 0.2 9 + 0.2<br />

DFLK 20 68.4 62.5 45.2 + 0.2 9 + 0.2<br />

DFLK 26 83.4 77.5 52.8 + 0.2 9 + 0.2<br />

3,2<br />

DFLK 34 103.4 97.5 63.0 + 0.2 9 + 0.2<br />

DFLK 40 128.4 122.5 70.6 + 0.2 9 + 0.2<br />

DFLK 50 143.4 137.5 83.3 + 0.2 9 + 0.2<br />

a<br />

b<br />

Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />

info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com<br />

PHOENIX CONTACT<br />

283