<strong>INTERFACE</strong> <strong>Cabling</strong><br />

VARIOFACE system cabling<br />

Siemens SIMATIC ® S7-400<br />

Front adapter<br />

The front adapters mean that<br />

preassembled system cables can be directly<br />

connected to I/O modules.<br />

FLKM 50-PA-S400<br />

– Transmission of max. 32 digital channels<br />

over one 50-position system cable.<br />

FLKM 50/4-FLK14/PA-S400<br />

– Transmission of max. 32 digital channels<br />

via one 14-position system cable.<br />

Perfectly fitting VARIOFACE termination<br />

boards with a variety of functions <strong>and</strong><br />

connection possibilities round off this<br />

system concept.<br />

FLKM 50-PA-S400 (3-48)<br />

– Analog channels are connected via a<br />

50-position system cable.<br />

The 1:1 connection of the adapter means<br />

that corresponding 1:1 interface modules<br />

are connected here<br />

Front adapter for I/O modules of the Siemens auto<strong>mation</strong><br />

equipment SIMATIC ® S7-400<br />

Card type<br />

Digital input<br />

Digital output<br />

FLKM 50-PA-S400<br />

6ES7 421-1BL01-0AA0<br />

6ES7 421-7BH01-0AB0*<br />

6ES7 421-7DH00-0AB0*<br />

6ES7 422-1BL00-0AA0<br />

6ES7 422-7BL00-0AB0<br />

FLKM 50-...PA-S400<br />

Front adapter for<br />

SIMATIC ® S7-400<br />

u P<br />

Description No. of pos. Type Order No.<br />

Pcs. /<br />

Pkt.<br />

VARIOFACE front adapter, for<br />

- SIMATIC ® S7-400, 1 x 32 channels can be<br />

50 FLKM 50-PA-S400 2294500 2<br />

connected<br />

- SIMATIC ® S7-400, 4 x 8 channels can be<br />

14 FLKM 50/ 4-FLK14/PA-S400 2294429 2<br />

connected<br />

- SIMATIC ® S7-400, only analog 50 FLKM 50-PA-S400(3-48) 2294908 2<br />

Technical data<br />

Max. perm. operating voltage<br />

< 50 V AC<br />

Max. permissible current<br />

1 A (per path)<br />

8 A (per connection, supply via separate power supply)<br />

Max. perm. total current<br />

2 A (per Byte, for supply via connector)<br />

8 A (during supply via a separate bridged power supply)<br />

Ambient temperature (operation) -20°C ... 50°C<br />

Ambient temperature (storage/transport) -20°C ... 70°C<br />

Mounting position<br />

Any<br />

St<strong>and</strong>ards/regulations IEC 60664 / DIN EN 50178 / IEC 62103<br />

Card type<br />

Digital input<br />

Digital output<br />

FLKM 50/4-FLK14/PA-S400<br />

6ES7 421-1BL01-0AA0<br />

6ES7 422-1BL00-0AA0<br />

6ES7 422-7BL00-0AB0<br />

Card type FLKM 50-PA-S400 (3-48)<br />

Analog input<br />

6ES7 431-0HH00-0AB0**<br />

6ES7 431-1KF00-0AB0**<br />

6ES7 431-1KF10-0AB0**<br />

6ES7 431-1KF20-0AB0**<br />

6ES7 431-7KF00-0AB0**<br />

6ES7 431-7KF10-0AB0**<br />

6ES7 431-7QH00-0AB0**<br />

Analog output<br />

6ES7 432-1HF00-0AB0**<br />

1 2 3 4 5 6 7 8 9 101112131415 1617181920 2122232425<br />

0+<br />

1+<br />

DR1<br />

1 2 3 4 5 6 7 8 9 101112131415161718192021222324<br />

1 2 3 4 5 6 7 8 9 101112131415 1617181920 2122232425<br />

26272829303132333435 363738394041424344454647484950<br />

DR2<br />

1 2 3 4 5 6 7 8 9 101112 131415161718192021222324<br />

2526272829303132333435363738394041424344454647484950<br />

* Only in connection with<br />

VIP-2/SC/FLK50/S7/A-S400, Order No.: 2322359<br />

All wire bridges (DR) on the adapter must be disconnected.<br />

** Only in connection with<br />

VIP-3/SC/FLK50, Order No.: 2315081<br />

UM 45-FLK 50/ZFKDS, Order No.: 2293585<br />

UM 45-FLKS 50/ZFKDS, Order No.: 2968470<br />

FLKM 50/KDS 3-MT/PPA/AN/PLC, Order No.: 2291587<br />

26272829303132333435 36373839404142434445464748<br />

Connection scheme FLKM 50-PA-S400 (3-48)<br />

2+<br />

3+<br />

–<br />

DR3<br />

252627282930313233343536373839404142434445464748<br />

Connection scheme FLKM 50-PA-S400<br />

9 11 13 1 2 3 4 5 6 7 8 10 12 14 9 11 13 1 2 3 4 5 6 7 8 10 12 14<br />

DR2<br />

DR1<br />

DR5<br />

DR4<br />

2 3 5 7 8<br />

14<br />

4 6 9 11 15 16 17 18 19 20 21 22 23<br />

1 10 12 13 24<br />

9 11 13 1 2 3 4 5 6 7 8 10 12 14 9 11 13 1 2 3 4 5 6 7 8 10 12 14<br />

Explanation:<br />

Flat-ribbon cable strip<br />

Connection to I/O card<br />

Screw terminal blocks for separate supply<br />

DR3<br />

DR6<br />

25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48<br />

Connection scheme: FLKM 50/4-FLK14/PA-S400<br />

L<br />

M<br />

214 PHOENIX CONTACT<br />

Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />

info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!