Feed-through terminal blocks for<br />

PLC-<strong>INTERFACE</strong><br />

<strong>INTERFACE</strong> <strong>Cabling</strong><br />

VARIOFACE system cabling<br />

The VARIOFACE PLC-VT terminals are<br />

passive feed-through terminal blocks, with<br />

the same shape as the 6.2 mm slim relay <strong>and</strong><br />

optocoupler interfaces PLC-<strong>INTERFACE</strong>. It<br />

is thus possible to implement 8-channel<br />

interface blocks for the system cabling,<br />

which can be adapted to a bit for the<br />

particular application. For individual<br />

requirements, the relay, optocoupler or the<br />

PLC-VT terminal blocks for passive signal<br />

transmission can be combined as needed.<br />

PLC-VT/ACT<br />

PLC-VT/ACT/LA<br />

– Can be combined with PLC-<strong>INTERFACE</strong><br />

actuator series<br />

– Signal path with two additional potential<br />

levels for free assignment (threeconductor<br />

connection)<br />

– Optionally with LED.<br />

The system connection is made via the<br />

PLC-V8 adapter.<br />

Note:<br />

Type of housing:<br />

Polyamide PA non-reinforced, color: green.<br />

For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />

Description<br />

No. of<br />

pos.<br />

H W<br />

D<br />

PLC-VT/ACT...<br />

VARIOFACE feed-through terminal blocks for<br />

PLC-<strong>INTERFACE</strong> actuator series<br />

u P F<br />

Module width<br />

W Type Order No. Pcs. /<br />

Pkt.<br />

VARIOFACE feed-through terminal block (three-wire<br />

connection), for PLC-<strong>INTERFACE</strong> actuator series<br />

6.2 mm PLC-VT/ACT 2295567 10<br />

VARIOFACE feed-through terminal block, same as before,<br />

however, with 24 V DC light indicator<br />

6.2 mm PLC-VT/ACT/LA 2296867 10<br />

Technical data PLC-VT/AKT PLC-VT/AKT/LA<br />

Max. perm. operating voltage Max. 250 V AC/DC 24 V DC<br />

Max. perm. current (per branch) 6 A (per signal conductor) 6 A (per signal conductor)<br />

Ambient temperature range -20°C ... 60°C -20°C ... 60°C<br />

Mounting position Any Any<br />

St<strong>and</strong>ards/regulations DIN EN 50178, IEC 62103<br />

Connection data solid / str<strong>and</strong>ed / AWG 0.2 ... 4 mm² / 0.2 ... 2.5 mm² / 24 - 12<br />

Dimensions H / D 94 mm / 80 mm<br />

2<br />

3<br />

1<br />

4<br />

5<br />

PLC-VT/ACT connection scheme<br />

2<br />

3<br />

1<br />

4<br />

Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />

info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com<br />

PLC-VT/ACT/LA connection scheme<br />

5<br />

PHOENIX CONTACT<br />

245