<strong>INTERFACE</strong> <strong>Cabling</strong><br />

VARIOFACE system cabling<br />

Front adapter for 32-channel cards of SIMATIC ® S7-300<br />

Card type<br />

Digital input<br />

VIP-PA-FLK50/...M/S7<br />

6ES7 321-1BL00-0AA0<br />

Digital output<br />

6ES7 322-1BL00-0AA0<br />

Digital input/output<br />

6ES7 323-1BL00-0AA0<br />

Analog input<br />

6ES7 331-7PF01-0AB0*<br />

6ES7 331-7PF11-0AB0*<br />

6ES7 331-7NF00-0AB0*<br />

6ES7 331-7NF10-0AB0*<br />

6ES7 331-1KF01-0AB0*<br />

Analog output<br />

6ES7 332-5HF00-0AB0*<br />

VIP-PA-FLK50/4X14/...M/S7<br />

Front adapter with system cable<br />

4 x 8 channels can be connected<br />

VIP-PA-FLK14/...M/S7<br />

Front adapter with system cable<br />

2 x 8 channels can be connected<br />

CPU<br />

Other modules<br />

312C<br />

313C<br />

314C<br />

6ES7 350-2AH01-0AE0*<br />

6ES7 357-4AH01-0AE0*<br />

SP<br />

SP<br />

- +<br />

- +<br />

BR bl<br />

9<br />

11<br />

1<br />

23456789<br />

13<br />

12345678<br />

10<br />

21<br />

22<br />

23<br />

24<br />

25<br />

26<br />

27<br />

28<br />

29<br />

30<br />

9<br />

11<br />

13<br />

1<br />

2345678<br />

10<br />

12<br />

14<br />

10<br />

12<br />

14<br />

9<br />

11<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

9<br />

11<br />

13<br />

1<br />

23456<br />

7<br />

8<br />

10<br />

12<br />

14<br />

31<br />

32<br />

33<br />

34<br />

35<br />

36<br />

37<br />

38<br />

39<br />

40<br />

13<br />

12345678<br />

10<br />

12<br />

BR rd<br />

14<br />

1<br />

Byte0<br />

9<br />

11<br />

13<br />

1<br />

2<br />

3<br />

45<br />

6<br />

78<br />

10<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

12<br />

14<br />

9<br />

11<br />

13<br />

Byte1<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

17<br />

18<br />

19<br />

20<br />

1<br />

2<br />

345<br />

6<br />

7<br />

8<br />

10<br />

12<br />

14<br />

SP<br />

+<br />

+<br />

-<br />

-<br />

SP<br />

BR rd<br />

BR bl<br />

Card type<br />

Digital input<br />

Digital output<br />

Digital input/output<br />

CPU<br />

VIP-PA-FLK50/4X14/...M/S7<br />

6ES7 321-1BL00-0AA0<br />

6ES7 322-1BL00-0AA0<br />

6ES7 323-1BL00-0AA0<br />

313C<br />

314C<br />

* Only in connection with<br />

VIP-2/SC/FLK50 (1-40)/S7, Order No.: 2315243,<br />

UM 45-FLK50/ZFKDS/S7-300, Order No.: 2968111,<br />

FLKM 50/KDS3-MT/PPA/S7-300, Order No.: 2304490.<br />

All bridges (BR) on the adapter must be disconnected.<br />

Type<br />

Order No.<br />

Pcs. /<br />

Pkt.<br />

Type<br />

Order No.<br />

VIP-PA-FLK50/4X14/ 0,5M/S7 2322553 1 VIP-PA-FLK14/ 0,5M/S7 2322663 1<br />

VIP-PA-FLK50/4X14/ 1,0M/S7 2322566 1 VIP-PA-FLK14/ 1,0M/S7 2322676 1<br />

VIP-PA-FLK50/4X14/ 1,5M/S7 2322579 1 VIP-PA-FLK14/ 1,5M/S7 2322689 1<br />

VIP-PA-FLK50/4X14/ 2,0M/S7 2321910 1 VIP-PA-FLK14/ 2,0M/S7 2321790 1<br />

VIP-PA-FLK50/4X14/ 2,5M/S7 2322582 1 VIP-PA-FLK14/ 2,5M/S7 2322692 1<br />

VIP-PA-FLK50/4X14/ 3,0M/S7 2322595 1 VIP-PA-FLK14/ 3,0M/S7 2322702 1<br />

VIP-PA-FLK50/4X14/ 4,0M/S7 2322605 1 VIP-PA-FLK14/ 4,0M/S7 2322715 1<br />

VIP-PA-FLK50/4X14/ 5,0M/S7 2322618 1 VIP-PA-FLK14/ 5,0M/S7 2322728 1<br />

VIP-PA-FLK50/4X14/ 6,0M/S7 2322621 1 VIP-PA-FLK14/ 6,0M/S7 2322731 1<br />

VIP-PA-FLK50/4X14/ 7,0M/S7 2322634 1 VIP-PA-FLK14/ 7,0M/S7 2322744 1<br />

VIP-PA-FLK50/4X14/ 8,0M/S7 2322647 1 VIP-PA-FLK14/ 8,0M/S7 2322757 1<br />

VIP-PA-FLK50/4X14/10,0M/S7 2322650 1 VIP-PA-FLK14/10,0M/S7 2322760 1<br />

60 V DC / < 50 V AC 60 V DC / < 50 V AC<br />

1 A (per path) 1 A (per path)<br />

8 A 8 A<br />

0.8 kV 0.8 kV<br />

0.16 Ω/m 0.16 Ω/m<br />

AWG 26 / 0.14 mm²<br />

AWG 26 / 0.14 mm²<br />

7 / Cu tin-plated 7 / Cu tin-plated<br />

6.4 mm 6.4 mm<br />

-20°C ... 50°C -20°C ... 50°C<br />

IEC 60664, IEC 62103, DIN EN 50178 IEC 60664, IEC 62103, DIN EN 50178<br />

Can be plugged onto 40-pos. I/O modules / separate power supply<br />

through terminal blocks with spring-cage double connection<br />

Can be plugged onto 20-pos. I/O modules / separate power supply<br />

through terminal blocks with spring-cage double connection<br />

Flat-ribbon cable connector 4 x 14-pos., as per IEC 60603-13 Flat-ribbon cable connector 2 x 14-pos., as per IEC 60603-13<br />

0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14 0.2 ... 2.5 mm² / 0.2 ... 2.5 mm² / 24 - 14<br />

Pcs. /<br />

Pkt.<br />

Front adapters for 16-channel cards of the SIMATIC ® S7-300<br />

Card type<br />

Digital input<br />

Digital output<br />

Digital input/output<br />

Analog input<br />

Analog output<br />

Analog input/output<br />

Other modules<br />

VIP-PA-FLK14/...M/S7<br />

6ES7 321-1BH02-0AA0<br />

6ES7 321-1BH10-0AA0<br />

6ES7 321-1BH50-0AA0*<br />

6ES7 321-7BH01-0AB0*<br />

6ES7 322-1BH01-0AA0<br />

6ES7 322-1BH10-0AA0<br />

6ES7 322-8BF00-0AB0*<br />

6ES7 323-1BH01-0AA0<br />

6ES7 331-7KF02-0AB0*<br />

6ES7 331-7HF01-0AB0*<br />

6ES7 331-7KB02-0AB0*<br />

6ES7 331-7TF01-0AB0<br />

6ES7 332-5HD01-0AB0*<br />

6ES7 332-5HB01-0AB0*<br />

6ES7 332-7ND02-0AB0*<br />

6ES7 334-0CE01-0AA0*<br />

6ES7 334-0KE00-0AB0*<br />

6ES7 335-7HG01-0AB0*<br />

6ES7 338-4BC01-0AB0*<br />

6ES7 350-1AH03-0AE0*<br />

6ES7 351-1AH01-0AE0*<br />

6ES7 352-1AH01-0AE0*<br />

6ES7 353-1AH01-0AE0*<br />

6ES7 354-1AH01-0AE0*<br />

6ES7 355-0VH10-0AE0*<br />

6ES7 355-1VH10-0AE0*<br />

* Only in connection with<br />

VIP-2/SC/2FLK14 (1-20)S7, Order No.: 2315230<br />

UM 45-2FLK14/ZFKDS/S7, Order No.: 2965156<br />

FLKM-2FLK14/KDS 3-MT/PPA/S7, Order No.: 2295062<br />

All bridges (BR) on the adapter must be disconnected.<br />

Note:<br />

The front adapters are delivered non-isolated.<br />

By removing the bridges, electrical isolation (in groups of 8) can be<br />

obtained.<br />

Explanation:<br />

Flat-ribbon cable strip<br />

Connection to I/O card<br />

SP: Separate power terminals<br />

BR bl : Plug-in bridge, blue<br />

BR rd : Plug-in bridge, red<br />

Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />

info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com<br />