<strong>INTERFACE</strong> <strong>Cabling</strong><br />
VARIOFACE wiring interface<br />
Miniature relay REL-MR<br />
The robust relays are used as interface<br />
relays throughout process <strong>and</strong> production<br />
engineering.<br />
The main features of these relays are their<br />
compact design, reliable electrical isolation,<br />
<strong>and</strong> compliance with the most important<br />
st<strong>and</strong>ards, as well as the number of variants.<br />
Note:<br />
For diagrams of operating voltage ranges,<br />
refer to page 176.<br />
Note:<br />
If the specified maximum values for multi-layer contact relays are<br />
exceeded, the gold plating is destroyed. The maximum values of the<br />
power contact relay are then valid. This can result in a shorter<br />
service life than with a pure power contact.<br />
REL-MR-G24/1<br />
Plug-in miniature relay<br />
1 N/O contact (1)<br />
Width 5<br />
A1 12<br />
P<br />
A2 11<br />
Description<br />
Plug-in miniature relay, with power contact<br />
Input voltage<br />
U N<br />
Type Order No.<br />
Pcs. /<br />
Pkt.<br />
1 12 V DC<br />
2 24 V DC REL-MR-G 24/1 2961037 8<br />
3 48 V DC<br />
4 60 V DC<br />
With power contact 5 110 V DC<br />
6 230 V AC<br />
Plug-in miniature relay, with multi-layer contact<br />
1 12 V DC<br />
2 24 V DC<br />
3 48 V DC<br />
4 60 V DC<br />
With gold contact 5 110 V DC<br />
6 230 V AC<br />
Technical data 1<br />
Input data<br />
Permissible range (based on U N ) -<br />
Permissible range (based on U N ) 0.8 -<br />
1.1<br />
Typ. input current at U N [mA] 5<br />
Typ. response time at U N [ms] 5<br />
Typ. response time at U N ( depending on phase relation )<br />
[ms]<br />
Typ. release time at U N [ms] 2<br />
Typ. release time at U N ( depending on phase relation )<br />
[ms]<br />
Output data<br />
<strong>Contact</strong> type<br />
Double contact, 1 N/O contact<br />
<strong>Contact</strong> material<br />
AgNi 90/10, + 5 µm hard gold-plated<br />
Max. switching voltage<br />
250 V AC / 125 V DC<br />
Min. switching voltage<br />
5 V DC<br />
Limiting continuous current<br />
3 A<br />
Max. inrush current<br />
5 A<br />
Max. interrupting rating, ohmic load<br />
250 V AC -<br />
General data<br />
Test voltage (winding / contact)<br />
2 kV AC (50 Hz, 1 min)<br />
Test voltage (contact/contact) -<br />
Ambient temperature range -40°C ... 85°C<br />
Rated operating mode<br />
100% operating factor<br />
Mechanical service life<br />
Approx. 2 x 10 7 cycles<br />
St<strong>and</strong>ards/regulations<br />
DIN VDE 0110, IEC 255/DIN VDE 0435 (in relevant parts)<br />
Assembly position/mounting<br />
Any<br />
Dimensions W / H / D 5 mm / 17 mm / 23 mm<br />
304 PHOENIX CONTACT<br />
Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />
info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com