Phoenix Contact INTERFACE System Cabling and ... - Power/mation
Phoenix Contact INTERFACE System Cabling and ... - Power/mation
Phoenix Contact INTERFACE System Cabling and ... - Power/mation
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Siemens SIMATIC ® S7-400<br />
Adapter for conversion from<br />
S5-135/155 to S7-400<br />
The FLKM S135/... adapters connect a<br />
SIMATIC ® S5 connector wired with<br />
individual conductors directly with the<br />
SIMATIC ® S7-400 basic card.<br />
The SIMATIC ® S5 connector is plugged<br />
directly onto an S7-400-I/O card with the<br />
help of an FFLKM S135/... intermediate<br />
adapter.<br />
A new SIMATIC ® S7-400 is installed in<br />
place of the SIMATIC ® S5. The existing field<br />
wiring remains intact.<br />
Attention:<br />
The LEDs of the S7-400 module are<br />
hidden.<br />
<strong>INTERFACE</strong> <strong>Cabling</strong><br />
VARIOFACE system cabling<br />
FLKM S135/...<br />
Adapter for Siemens SIMATIC ® S5-135/S7-400<br />
Description No. of pos. Type Order No.<br />
Digital IN 24 V from S5-135/155 to S7-400<br />
Pcs. /<br />
Pkt.<br />
6ES5 420-4UA14 on 6ES7 421-1BL01-0AA0 1 FLKM S135/S400/SO120 2301723 1<br />
6ES5 430-4UA14 on 6ES7 421-1BL01-0AA0 2 FLKM S135/S400/SO121 2301736 1<br />
6ES5 431-4UA12 to 6ES7 421-7DH00-0AB0 3 FLKM S135-431-4UA/S400 2314846 1<br />
6ES5 432-4UA12 on 6ES7 421-1BL01-0AA0 4 FLKM S135/S400/SO122 2301749 1<br />
Technical data 1 2 3 4<br />
Max. perm. operating voltage 24 V AC/DC 60 V DC 24 V DC 24 V AC/DC<br />
Max. permissible current 4 A (per path) 2 A (per path) 4 A (per path) 4 A (per path)<br />
4 A (per<br />
connection,<br />
supply via<br />
separate<br />
power supply)<br />
2 A (during<br />
supply via<br />
separate<br />
power supply)<br />
4 A (per<br />
connection,<br />
supply via<br />
separate<br />
power supply)<br />
4 A (per<br />
connection,<br />
supply via<br />
separate<br />
power supply)<br />
Test voltage (contact/contact) 500 V (50 Hz, 1<br />
min)<br />
1.25 kV (50 Hz,<br />
1 min)<br />
1.25 kV (50 Hz,<br />
1 min)<br />
1.25 kV (50 Hz,<br />
1 min)<br />
Ambient temperature (operation) -20°C ... 50°C -20°C ... 50°C -20°C ... 50°C -20°C ... 50°C<br />
Mounting position Any Any Any Any<br />
St<strong>and</strong>ards/regulations DIN EN 50178 / IEC 62103<br />
S7-400 1 2 3 4 5 6 7 8 9 10 1112 1314<br />
1516171819202122<br />
2324<br />
S7-400<br />
1 2 3 4 5 6 7 8 9 10 11 15 16 17 18 19 2021<br />
22<br />
L+<br />
S5-135 1 2 3 4<br />
5 6 7 8 9 10 1112 1314<br />
1516171819<br />
202122 2324<br />
S5-135 1 4 5 6 7 8 9 10 11 13 14 15 16 17 1819<br />
20<br />
S7-400 2526<br />
2728293031323334<br />
3536<br />
3738<br />
3940414243444546 4748<br />
S7-400 27 28 29 30 3132 33 34 39 4041<br />
42 43 44 45 46 48<br />
M<br />
S5-135 2526<br />
2728293031323334<br />
3536<br />
3738<br />
39404142<br />
S5-135 25 26 27 28 29 30 31 32 34 3536<br />
37 38 39 40 41<br />
FLKM S135-431-UA/S400 connection scheme<br />
Connection scheme: FLKM S135/S400/SO120<br />
S7-400 1 2 3 4 5 6 7 8 9 10 11 15161718192021<br />
22<br />
S7-400 1 2 3 4 5 6 7 8 9 10 11 15161718192021<br />
22<br />
L+<br />
S5-135 4 5 6 7 8 9 10 11 13141516171819<br />
20<br />
S5-135 1 2 3 4 5 6 7 8 9 10 11 13141516171819<br />
20<br />
S7-400 27282930 31323334 394041<br />
4243444546 48<br />
M<br />
S7-400 27282930 31323334 394041<br />
4243444546 48<br />
M<br />
M<br />
S5-135 2526272829303132 343536<br />
3738394041 21 42 12 33<br />
S5-135 2526272829303132 343536<br />
3738394041 21 42<br />
Connection scheme: FLKM S135/S400/SO122<br />
Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />
info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com<br />
Connection scheme: FLKM S135/S400/SO121<br />
PHOENIX CONTACT<br />
215