<strong>INTERFACE</strong> <strong>Cabling</strong><br />

VARIOFACE wiring interface<br />

Modules for ELCO connectors for use<br />

in Ex i circuits<br />

The VARIOFACE modules connect ELCO<br />

connectors of the 8016 series to screw<br />

connection terminal blocks. The modules<br />

for ELCO connectors can be used as simple<br />

electrical equipment for applications in<br />

intrinsically safe circuits as per<br />

EN 60079-14. They fulfill the requirements<br />

of the intrinsic safety as per EN 60079-11<br />

(EN 50020) <strong>and</strong> can be used for various<br />

intrinsically safe circuits taking into account<br />

the pin configuration.<br />

The voltage of an intrinsically safe circuit<br />

must not exceed 30 V. The voltage<br />

difference between two intrinsically safe<br />

circuits can be up to 60 V.<br />

The modules are equipped with blue<br />

screw connection methods are clear<br />

labeling for intrinsically safe circuits.<br />

The arrangement of angled ELCO<br />

connectors makes it possible to lead the<br />

lines led out from the cable housing away<br />

from the adjacent modules without any<br />

negative effects.<br />

For the disconnection of intrinsically safe<br />

<strong>and</strong> non-intrinsically safe circuits, a distance<br />

of at least 50 mm should be kept between<br />

the connection points using partition plates<br />

or spaces.<br />

Note:<br />

For dimensional drawings <strong>and</strong> pin<br />

assignments, refer to page 315.<br />

For details about explosion protection,<br />

see page 424.<br />

Notes:<br />

Type of housing:<br />

Polyamide PA non-reinforced, color: green.<br />

For marking systems <strong>and</strong> mounting material, see CLIPLINE catalog.<br />

Description<br />

No. of<br />

pos.<br />

H W<br />

D<br />

UMK-EC90/32/EX...<br />

32-pos.<br />

solid str<strong>and</strong>ed<br />

[mm 2 ] AWG<br />

Connection data<br />

Screw connection 0.2-4 0.2-2.5 24-12<br />

Module width<br />

W Type Order No. Pcs. /<br />

Pkt.<br />

VARIOFACE module, with:<br />

- Pin strip 8016 right above 32 101.30 UMK- EC90/32/EX-XOR 2900109 1<br />

- Pin strip 8016 right below 32 101.30 UMK- EC90/32/EX-XUR 2969068 1<br />

- Pin strip 8016 left above 32 101.30 UMK- EC90/32/EX-XOL 2900110 1<br />

- Pin strip 8016 left above 32 101.30 UMK- EC90/32/EX-XUL 2969071 1<br />

VARIOFACE module, with:<br />

- Pin strip 8016 right 25 78.80<br />

- Pin strip 8016 left 25 78.80<br />

VARIOFACE module, with:<br />

- Pin strip 8016 right 25 77.00<br />

- Pin strip 8016 left 25 77.00<br />

Technical data<br />

Operating voltage<br />

Max. 30 V DC<br />

Max. perm. current (per branch)<br />

500 mA<br />

Test voltage<br />

500 V (50 Hz, 1 min)<br />

Ambient temperature range -20°C ... 50°C<br />

Mounting position<br />

Any<br />

St<strong>and</strong>ards/regulations EN 60079-11<br />

Dimensions H / D 58.5 mm / 77 mm<br />

294 PHOENIX CONTACT<br />

Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />

info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com