Phoenix Contact INTERFACE System Cabling and ... - Power/mation
Phoenix Contact INTERFACE System Cabling and ... - Power/mation
Phoenix Contact INTERFACE System Cabling and ... - Power/mation
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>INTERFACE</strong> <strong>Cabling</strong><br />
VARIOFACE system cabling<br />
Allen Bradley ControlLogix,<br />
Honeywell PlantScape<br />
Front adapter<br />
The front adapters mean that<br />
preassembled system cables can be directly<br />
connected to I/O modules. The front<br />
adapters are pushed into the tall 1756-TBE<br />
covers (original accessories, not included in<br />
the scope of delivery, must be ordered<br />
directly from manufacturer) of the<br />
controller.<br />
There are two connection possibilities<br />
available:<br />
– Transmission of max. 32 channels over<br />
one 50-position system cable,<br />
– Transmission of max. 2 x 8 channels over<br />
two 14-position system cables.<br />
Perfectly fitting VARIOFACE termination<br />
boards round off this system concept.<br />
Notes:<br />
Front adapters can also be used without cover.<br />
FLKM...-PA-AB/1756/...<br />
Front adapters for Allen Bradley ControlLogix <strong>and</strong><br />
Honeywell PlantScape<br />
Description No. of pos. Type Order No.<br />
Pcs. /<br />
Pkt.<br />
VARIOFACE front adapter, for<br />
- ControlLogix, max. 1 x 32 channels can be<br />
50 FLKM 50-PA-AB/1756/EXTC 2302735 1<br />
connected<br />
- ControlLogix, input card IB 32 50 FLKM 50-PA-AB/1756/IN/EXTC 2302748 1<br />
VARIOFACE front adapter, for<br />
- ControlLogix, max. 2 x 8 channels can be<br />
14 FLKM 14-PA-AB/1756/EXTC 2302861 1<br />
connected<br />
– ControlLogix, input card IA 16, IB 16, IC 16, IN 16 14 FLKM 14-PA-AB/1756/IN/EXTC 2302874 1<br />
u<br />
Front adapter for I/O modules of the auto<strong>mation</strong> equipment<br />
from Allen Bradley ControlLogix <strong>and</strong> Honeywell PlantScape<br />
Card type<br />
FLKM 50-PA-AB/1756/EXTC<br />
Digital input 1756-IA 16 I* or TC-TDK 161*<br />
1756-IB 16 D* or TC-TDX 161*<br />
1756-IB 16 I* or TC-TDJ 161*<br />
1756-IH 16 I*<br />
Digital output 1756-OB 32 or TC-ODD 321<br />
Analog input 1756-IF 8 *<br />
1756-IF 16 I* or TC-IAH 161*<br />
Counter<br />
1756-HSC*<br />
Servo<br />
1756-M02 AE*<br />
Technical data<br />
Max. perm. operating voltage<br />
Max. permissible current<br />
< 50 V AC<br />
1 A (per path)<br />
8 A (per connection, supply via separate power supply)<br />
Ambient temperature (operation) -20°C ... 50°C<br />
Ambient temperature (storage/transport) -20°C ... 70°C<br />
Connection data solid / str<strong>and</strong>ed / AWG 0.14 ... 1.5 mm² / 0.14 ... 1.5 mm² / 28 - 16<br />
St<strong>and</strong>ards/regulations IEC 60664 / DIN EN 50178 / IEC 62103<br />
Card type<br />
FLKM 50-PA-AB/1756/IN/EXTC<br />
Digital input 1756-IB 32 or TC-IDD 321<br />
Card type<br />
FLKM 14-PA-AB/1756/EXTC<br />
Digital input 1756-IA 8 D** or TC-IDX 081*<br />
Digital output<br />
1756-OB 16 E<br />
Analog input 1756-IF 6 I** or TC-IAH 061**<br />
1756-IR 6 I** or TC-IXR 061**<br />
1756-IT 6 I** or TC-IXL 061**<br />
Analog output<br />
1756-OF 4 I**<br />
1756-OF 6 CI** or TC-OAH 061**<br />
1756-OF 6 VI** or TC-OAV 061**<br />
1756-OF 8** or TC-OAV 081**<br />
Switch<br />
1756-PLS**<br />
Card type<br />
FLKM 14-PA-AB/1756/IN/EXTC<br />
Digital input 1756-IN 16**<br />
1756-IA 16 or TC-IDA 161**<br />
1756-IB 16<br />
1756-IC 16**<br />
* Only in connection with<br />
UM 45-FLK 50/AB-1756, Order No.: 2968357.<br />
No voltage supply may take place on the front adapter.<br />
Danger of short circuit!<br />
0+<br />
0-<br />
1+<br />
1-<br />
1 2 3 4 5 6 7 8 9 1011121314 1 2 3 4 5 6 7 8 9 1011121314<br />
1 2 3 4 5 6 7 8 9 10 11121314151617181920<br />
Connection scheme: FLKM 14-PA-AB/1756/EXTC<br />
1 2 3 4 5 6 7 8 9 1011121314 1 2 3 4 5 6 7 8 9 1011121314<br />
0-<br />
0+<br />
1-<br />
1+<br />
1 2 3 4 5 6 7 8 9 101112131415161718192021222324<br />
1 2 3 4 5 6 7 8 9 101112131415161718<br />
2526272829303132333435363738394041424344454647484950<br />
NCNC<br />
1920212223242526 27282930313233343536<br />
Connection scheme: FLKM 50-PA-AB/1756/EXTC<br />
1 2 3 4 5 6 7 8 9 101112131415161718192021222324<br />
** Only in connection with<br />
UM 45-2FLK 14/AB-1756, Order No.: 2968360.<br />
No voltage supply may take place on the front adapter.<br />
Danger of short circuit!<br />
Explanation:<br />
Flat-ribbon cable strip<br />
Connection to I/O card<br />
Screw terminal blocks for separate supply<br />
0-<br />
0-<br />
1-<br />
1-<br />
1 2 3 4 5 6 7 8 9 10 11121314151617181920<br />
Connection scheme: FLKM 14-PA-AB/1756/IN/EXTC<br />
0-<br />
0-<br />
1-<br />
1-<br />
1 2 3 4 5 6 7 8 9 101112131415161718<br />
2526272829303132333435363738394041424344454647484950<br />
NCNC<br />
1920212223242526 27282930313233343536<br />
Connection scheme: FLKM 50-PA-AB/1756/IN/EXTC<br />
190 PHOENIX CONTACT<br />
Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />
info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com