22.04.2014 Views

Phoenix Contact INTERFACE System Cabling and ... - Power/mation

Phoenix Contact INTERFACE System Cabling and ... - Power/mation

Phoenix Contact INTERFACE System Cabling and ... - Power/mation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>INTERFACE</strong> <strong>Cabling</strong><br />

VARIOFACE system cabling<br />

<strong>System</strong> cable with flat-ribbon cable<br />

connector<br />

Special lengths<br />

Pre-assembled round cables are used<br />

to connect the PLC front adapters to the<br />

corresponding VARIOFACE termination<br />

boards. Connector strips are fitted on both<br />

ends of the cables in accordance with<br />

IEC 60603-13/DIN 41651. In case of<br />

shielded cables, a cable end with a ferrule is<br />

additionally provided as a shield connection<br />

(length: Approx. 0.5 m; cable H05V-K<br />

1mm 2 , black).<br />

The order key for special lengths is<br />

defined by three features.<br />

The features in the appropriate<br />

sequence are:<br />

– Cable type<br />

– Assembly,<br />

– Length in meters.<br />

There are two order keys, one for the<br />

non-shielded round cable FLK EZ-<br />

DR/.../.../... <strong>and</strong> one for the shielded round<br />

cable FLK EZ-DR-S/.../.../.... The features<br />

necessary for clear identification of an order<br />

are described below:<br />

Cable type<br />

– The number of individual conductors of<br />

the cable is defined here.<br />

Assembly<br />

– None,<br />

the cable is not assembled at either end;<br />

– socket strip at both ends, 10-pos.,<br />

the cable is fitted at both ends with<br />

10-pos. connectors (1:1 connection);<br />

– socket strip at both ends, 14-pos.,<br />

the cable is fitted at both ends with<br />

14-pos. connectors (1:1 connection);<br />

– socket strip at both ends, 50-pos.,<br />

the cable is fitted at both ends with<br />

50-pos. connectors (1:1 connection);<br />

– socket strip at one end, 14-pos.,<br />

socket strip at one end, 16-pos.,<br />

the cable is fitted with a 14-pos.<br />

connector at one end <strong>and</strong> with a 16-pos.<br />

connector at the other (for SIMATIC S7;<br />

no 1:1 connection).<br />

Features of permissible assemblies:<br />

Cable type<br />

Non-shielded round cables<br />

FLK EZ-DR.../.../...<br />

Shielded round cables<br />

FLK EZ-DR-S.../.../...<br />

Assembly 10-pos. 14-pos. 16-pos. 20-pos. 26-pos. 34-pos. 40-pos. 50-pos. 14-pos. 16-pos. 40-pos. 50-pos.<br />

no assembly 10U/C00/... 14U/C00/... 16U/C00/... 20U/C00/... 26U/C00/... 34U/C00/... 40U/C00/... 50U/C00/... 14S/C00/... 16S/C00/.... 40S/C00/... 50S/C00/...<br />

socket strip at both ends, 10-pos. 10U/C55/... 1 )<br />

socket strip at both ends, 14-pos. 14U/C23/... 1 ) 14S/C23/... 1 )<br />

socket strip at both ends, 16-pos. 16U/C58/... 1 ) 16S/C58/... 1 )<br />

socket strip at both ends, 20-pos. 20U/C61/... 1 )<br />

socket strip at both ends, 26-pos. 26U/C63/... 1 )<br />

socket strip at both ends, 34-pos. 34U/C65/... 1 )<br />

socket strip at both ends, 40-pos. 40U/C30/... 3 ) 40S/C30/... 3 )<br />

socket strip at both ends, 50-pos. 50U/C38/... 2 ) 50S/C38/... 2 )<br />

socket strip at one end, 14-pos.;<br />

socket strip at one end, 16-pos. 14U/C52/... 1 ) 14S/C52/... 1 )<br />

1 ) straight socket strips fitted at both ends.<br />

Shield connection<br />

(for shielded<br />

cables)<br />

2 ) Socket strips fitted, straight at one end <strong>and</strong> angled at the<br />

other.<br />

Shield connection<br />

(for shielded cables)<br />

3 ) Socket strips fitted, straight at one end <strong>and</strong> angled at the<br />

other.<br />

Shield connection<br />

(for shielded<br />

cables)<br />

Polarity protection lug<br />

Polarity protection lug<br />

Polarity protection lug<br />

Polarity protection lug<br />

Polarity protection lug<br />

Polarity protection lug<br />

Sample order for round cable unshielded:<br />

– Unshielded 50-position round cable sets with two 50-pos. socket strips <strong>and</strong> a length of 11.5 m<br />

Quantity Order No. Cable type Assembly Length [m] 4 )<br />

1 2295059 / 50U / C38 / 11.50<br />

10U = 10-pos. unshielded<br />

14U = 14-pos. unshielded<br />

16U = 16-pos. unshielded<br />

20U = 20-pos. unshielded<br />

26U = 26-pos. unshielded<br />

34U = 34-pos. unshielded<br />

40U = 40-pos. unshielded<br />

50U = 50-pos. unshielded<br />

Sample orders for round cable shielded:<br />

– Shielded 14-position round cable sets with two 14-pos. socket strips <strong>and</strong> a length of 12.75 m<br />

C00 = no assembly<br />

C55 = 10-pos. socket strip at both ends<br />

C23 = 14-pos. socket strip at both ends<br />

C52 = 14-pos. socket strip at one end<br />

16-pos. socket strip at one end (for S7)<br />

C58 = 16-pos. socket strip at both ends<br />

C61 = 20-pos. socket strip at both ends<br />

C63 = 26-pos. socket strip at both ends<br />

C65 = 34-pos. socket strip at both ends<br />

C30 = 40-pos. socket strip at both ends<br />

C38 = 50-pos. socket strip at both ends<br />

4 )min. 0.20 m<br />

Quantity Order No. Cable type Assembly Length [m] 4 )<br />

1 2295046 / 14S / C23 / 12.75<br />

14S = 14-pos. shielded<br />

16S = 16-pos. shielded<br />

40S = 40-pos. shielded<br />

50S = 50-pos. shielded<br />

C00 = no assembly<br />

C23 = 14-pos. socket strip at both ends<br />

C52 = 14-pos. socket strip at one end<br />

16-pos. socket strip at one end (for S7)<br />

C58 = 16-pos. socket strip at both ends<br />

C30 = 40-pos. socket strip at both ends<br />

C38 = 50-pos. socket strip at both ends<br />

4) min. 0.20 m<br />

268 PHOENIX CONTACT<br />

Courtesy of <strong>Power</strong>/<strong>mation</strong>. 1310 Energy Lane, Saint Paul, MN 55108<br />

info@power<strong>mation</strong>.com - 800-843-9859 - www.power<strong>mation</strong>.com

Hooray! Your file is uploaded and ready to be published.