plc function ref - 34.23<br />

COP - file COPy<br />

A<br />

COP<br />

COPY FILE<br />

Source<br />

Dest<br />

Length<br />

#N7:50<br />

#N7:20<br />

4<br />

Description:<br />

Status Bits:<br />

Registers:<br />

This instruction copies from one list to another. When ’A’ is true the<br />

instruction will copy the entire source list to the destination location in<br />

a single scan. In this example this would mean N7:20=N7:50,<br />

N7:21=N7:51, N7:22=N7:52 <strong>and</strong> N7:23=N7:53. The source values<br />

are not changed. This instruction will not convert data types.<br />

none<br />

none<br />

Available on: Micrologix, PLC-5