2.3.3 GEOMETRIC REQUIREMENTS<br />

2.3.3.1 SPEED RESTRAINT<br />

Vehicle speeds on industrial and commercial roads should be<br />

restrained to the design target speeds by the use of horizontal<br />

deflection. This can be achieved using the following criteria:<br />

• distances between speed restraint devices shall not be<br />

greater than 150m.<br />

• centre line radii for speed attenuation curves shall be no<br />

greater than 40m.<br />

• the length of the separating straight between attenuation<br />

curves of opposite hand shall be no greater then 24m<br />

2.3.3.2 JUNCTIONS<br />

Junction arrangements involving industrial and commercial local<br />

distributor and access roads shall be designed in accordance with the<br />

following criteria:<br />

• layout configurations between industrial and commercial<br />

local distributor roads and primary distributor roads will<br />

depend on traffic flow and turning proportions. Details<br />

shall be in accordance with the requirements of the<br />

<strong>Design</strong> Manual for Roads and Bridges, published by the<br />

DETR Volume 6 TD42/95 or TD 16/93 (roundabouts).<br />

• layout configurations between industrial and commercial<br />

access roads and local distributor roads or other vehicle<br />

dominated environments shall be simple ‘T’ junctions.<br />

• minimum spacing between road centre-lines at junctions<br />

will be as follows:<br />

• 90m - for side roads which join the priority road on<br />

the same side<br />

• 15m - for side roads which join the priority road on<br />

opposite sides where there is a right-left stagger<br />

• 40m - for side roads which join the priority road on<br />

opposite sides where there is a left-right stagger<br />

• It is recommended that right-left stagger junction<br />

arrangements be used instead of left-right arrangements<br />

in order to reduce vehicle conflict.<br />

2.3.3.3 RADII<br />

Radii for junction arrangements involving both industrial and<br />

commercial local distributor and access roads shall be in accordance<br />

with the following criteria:<br />

• 15m - minimum required for all corners and access<br />

entrances.<br />

• tapered kerb lengths equal to 1 in10 (10%) are required<br />

immediately after the tangent points of the radii:<br />

• along the near side of the non-priority road for vehicles<br />

exiting the priority road<br />

• along the near side of the priority road for vehicles<br />

exiting the non-priority road<br />

• footway construction around corners shall be strengthened<br />

in accordance with tables 19 and 21 in section 3.7.<br />

2.3.3.4 RIGHT TURN FACILITIES<br />

A right turning facility is required where the non-priority road type is:<br />

• an industrial or commercial local distributor<br />

30<br />

<strong>Kent</strong><br />

<strong>Design</strong><br />

• an industrial or commercial access road which serves more<br />

than 15,000m 2 of gross floor space, and the priority road is<br />

either a primary distributor or industrial distributor.<br />

2.3.3.5 VISIBILITY<br />

To ensure that drivers of vehicles can both see and been seen by<br />

other drivers at junctions, around bends and at entrances to<br />

premises, unobstructed visibility is required as follows:<br />

Inter-visibility must be provided between 1.05 and 2m.<br />

Junction visibility shall be provided in accordance with the following<br />

requirements:<br />

• ‘X’ distance - 4.5m<br />

• ‘Y’ distance - 70m<br />

Where traffic flows are expected to exceed 300 vehicle movements<br />

per hour the ‘x’ distance should be increased to 9m.<br />

Where the priority road is an existing road the ‘Y’ distance shall<br />

relate to the existing measured 85 percentile wet weather speed on<br />

the priority road. Advice relating to wet weather speeds and visibility<br />

is set out in Planning Policy Guidance PPG 13 and <strong>Design</strong><br />

Bulletin 32. All ‘Y’ distances relating to existing roads shall not be<br />

less than 70m.<br />

Visibility around bends is related to vehicle stopping distances and shall<br />

be determined in accordance with the criteria set out in <strong>Design</strong><br />

Bulletin 32.<br />

Visibility at all vehicular accesses shall be provided in accordance with<br />

the following requirements:<br />

• ‘X’ distance - 2m<br />

• ‘Y’ distance - 70m<br />

Where speed restraint measures are introduced along the road the<br />

‘Y’ distance can be reduced to 60m.<br />

2.3.3.6 CARRIAGEWAY WIDTHS<br />

A carriageway width of 7.3m is required for both industrial and<br />

commercial local distributor and access roads. Widening around<br />

bends shall be in accordance with criteria set out in ‘<strong>Design</strong>ing for<br />

Deliveries’ published by the Freight Transport Association.<br />

2.3.3.7 CENTRE LINE RADII<br />

A minimum centre line radius of 40m is required for both industrial<br />

and commercial local distributor and access roads.<br />

2.3.3.8 GRADIENTS<br />

• Longitudinal Gradients<br />

Both industrial and commercial local distributor and access roads shall<br />

have a maximum longitudinal gradient of 6% (1 in 16.7) and a<br />

minimum longitudinal gradient of 1.25% (1 in 80), except at junctions.<br />

• Junction Gradients<br />

At junctions the gradient shall not exceed 5% (1 in 20) when rising<br />

and 4% (1 in 25) when falling towards the priority road for a distance<br />

equal to twice the junction radii measured from the line of the<br />

priority road.<br />

• Cross-Sectional Gradient.<br />

Both industrial and commercial local distributor and access roads<br />

shall have a cross-sectional gradient of 2.5% (1 in 40). Changes in<br />

cross-sectional gradient from crossfall to cambered should be<br />

avoided where the longitudinal gradient is flat.<br />

• Vertical Curves.<br />

Vertical curves should be provided at summit and sag points for all<br />

changes of gradient in accordance with section 2.2.2.4.