significantly decreased from a cooler top flange, while the maximum temperatures<br />

found in the lower flange <strong>and</strong> web are not affected by the presence of a concrete<br />

slab. This means that the presence of the concrete slab will not change the failure<br />

temperature of the lower flange <strong>and</strong> therefore not change the failure temperature of<br />

the member.<br />

It is therefore recommended that one equation is used to estimate the limiting<br />

temperature of a steel member <strong>and</strong> that the four sided section factor is used in the<br />

equation. The ECCS formula, equation 4.2, gives the best correlation to the<br />

maximum temperature in the member from the results seen in Section 0.<br />

4.4 COMPARISONS WITH OTHER FINITE ELEMENT<br />

PROGRAMMES:<br />

4.4.1 Comparison of <strong>FIRE</strong>S-T2 with SAFIR:<br />

<strong>FIRE</strong>S-T2 is a computer programme that evaluates the temperature history of two<br />

dimensional structures in fire environments. The solutions are found through finite<br />

element modelling coupled with time step integration. The same heat transfer<br />

principles are applied to the formulations made in <strong>FIRE</strong>S-T2 as in SAFIR so the<br />

results should be similar.<br />

1000<br />

Temperature ( o C)<br />

800<br />

600<br />

400<br />

200<br />

0<br />

0 10 20 30 40 50 60 70<br />

Time (min)<br />

<strong>FIRE</strong>S-T2<br />

SAFIR<br />

Figure 4.13: Comparison between the results from the SAFIR programme with temperature results<br />

from <strong>FIRE</strong>S-T2 for the unprotected 530 UB 82.0 beam with three sided exposure <strong>and</strong> a concrete<br />