R-404A PERFORMANCE DATA<br />

MODEL: F-1000MLF & MLF-C (cubelet)<br />

Total Amperage 1.63A Supply voltage: 115/60/1<br />

This unit is designed for connection to a Rack System using R-404A refrigerant. The data below is calculated.<br />

Ambient Temp °F/°C<br />

70 / 21 80 / 27<br />

90 / 32<br />

Kg=lbs.<br />

x .454<br />

Production<br />

24 hours<br />

(lbs.)<br />

Evaporator<br />

Outlet temp.<br />

(°F)<br />

Pressure<br />

High Side<br />

Pressure<br />

Suction<br />

Water Temp<br />

°F/°C<br />

50 / 9<br />

70 / 21<br />

90 / 32<br />

50 / 9<br />

70 / 21<br />

90 / 32<br />

50 / 9<br />

70 / 21<br />

90 / 32<br />

50 / 9<br />

70 / 21<br />

90 / 32<br />

Low side -C Low side -C<br />

1150<br />

1035<br />

1005<br />

21<br />

21<br />

21<br />

106<br />

106<br />

106<br />

26<br />

26<br />

26<br />

1020<br />

945<br />

915<br />

21<br />

21<br />

21<br />

106<br />

106<br />

106<br />

26<br />

26<br />

26<br />

980<br />

950<br />

925<br />

21<br />

21<br />

21<br />

125<br />

125<br />

125<br />

30<br />

30<br />

30<br />

885<br />

860<br />

835<br />

21<br />

21<br />

21<br />

125<br />

125<br />

125<br />

30<br />

30<br />

30<br />

Low side -C<br />

900<br />

885<br />

805<br />

21<br />

21<br />

23<br />

143<br />

143<br />

143<br />

33<br />

33<br />

33<br />

805<br />

795<br />

760<br />

21<br />

21<br />

23<br />

143<br />

143<br />

143<br />

33<br />

33<br />

33<br />

100 / 38<br />

Low side -C<br />

830<br />

805<br />

690<br />

23<br />

23<br />

23<br />

166<br />

166<br />

166<br />

35<br />

35<br />

35<br />

735<br />

710<br />

640<br />

23<br />

23<br />

23<br />

166<br />

166<br />

166<br />

35<br />

35<br />

35<br />

Note: The data provided is calculated by using a refrigeration capacity of 5700 BTU/h with a high side pressure of 213 PSIG and suction<br />

pressure of 31.2 PSIG. The actual production and system operating pressures will vary depending on the specific R-404A rack system<br />

setup.<br />

Factory setting for the Evaporator Pressure Regulating Valve (EPR) is 32 PSIG. for evaporator temperature no less than 0 °F (-17.7°C).<br />

174<br />