HEAT LOAD FOR R-404A MODELS<br />

The heat of rejection information listed below by model<br />

number should be used for sizing air conditioning equipment<br />

or water-cooled cooling tower applications.<br />

CUBERS: AIR WATER-COOLED<br />

MODEL COOLED (CONDENSER ONLY)<br />

KM-150B 3100 2800<br />

KM-150B -E 3400 2900<br />

KM-250BAF 5064 5707<br />

KML-250M 5560 5000<br />

KML-350M 6550 5370<br />

KM-280M & -E 8159 6773<br />

KML-450M 7480 6180<br />

KM-500M 8206 6663<br />

KM-500M -E 7371 6876<br />

KML-600M 11580 12635<br />

KM-630M -E 10375 12635<br />

KM-900M 14800 14400<br />

KM-1300S/M 19800 17150<br />

KM-1300S3 18130 15450<br />

KM-1300S -E 20400 17925<br />

KM-1600SWF —- 18000<br />

KM-1600SWF3 —- 17560<br />

KM-1800SAH 24720 —-<br />

KM-1800SAH3 24150 —-<br />

KM-2000SWF3 —- 22700<br />

HEAT LOAD - R-404A FLAKERS/DCM’S<br />

MODEL AIR WATER-COOLED<br />

COOLED (CONDENSER ONLY)<br />

F-300B 3178 —-<br />

F-450M 5090 —-<br />

F-500B 4683 —-<br />

F-800M 7500 6270<br />

F-1000M 9050 7110<br />

F-1000M/50 9000 7000<br />

F-1001M 9050 7110<br />

F-2000M —- 15530<br />

DCM-240B 3800 —-<br />

DCM-270B 3532 —-<br />

DCM-500B 6300 5575<br />

DCM-750B 8314 5130<br />

Figures shown are at 90° F air temp. 70° F water temp.<br />

Allow for a pressure diffenential of 7 psi across the<br />

water cooled condenser.<br />

18<br />

12/01/02 12/20/03<br />

2/20/03