4. Melt away of back of cube<br />

a) This can occur if the evaporator plate is scaled up.<br />

De-scaling is required.<br />

b) Insufficient water flow during harvest can also cause<br />

the flat side of the cube to melt away. Check for a<br />

plugged inlet water valve screen, plugged external<br />

filter, low water pressure, or a small water line size.<br />

EITHER OR BOTH OF THESE ITEMS CAN CAUSE<br />

THIS SYMPTOM.<br />

5. Small cube<br />

(Size will depend on how much water is<br />

in the reservoir.)<br />

a) Can be caused by a low volume of water at the beginning<br />

of freeze. Check for adequate water flow during<br />

harvest. See item 4 b)<br />

b) If the pump out check valve is stuck open or has a<br />

weak spring, the water left in the reservoir will be<br />

pumped out during the first five minutes of freeze.<br />

This results in a short cycle and slivers of ice or small<br />

cubes.<br />

c) Any loss of water, whether by leak, water trail, or<br />

loose stand pipe can cause this problem.<br />

6. Freeze ups can be caused by 2, 3, or 4 above in any<br />

combination. The major cause however is a dirty<br />

(scaled up ) water system or evaporator. A thorough<br />

cleaning will eliminate most freeze ups. The second<br />

most common reason for freeze up is low water flow.<br />

Always check the evaporator, and water flow first,<br />

then go to other checks when diagnosing freeze ups.<br />