acket. When installing, make sure the bracket points<br />

downward so that the cubes will easily fall away from the<br />

bin control bulb.<br />

___<br />

When replacing a thermostatic bin control, check the operation<br />

by holding ice against the thermostatic bulb with the<br />

control switch in the wash position. The pump should stop<br />

within 6 to 10 seconds. Adjustment up to 30~45 seconds<br />

could be acceptable depending on the application. Adjust<br />

the control “CCW” for a faster shut down.<br />

Note: Control board dip switch number 7 must be OFF for<br />

this control to operate the unit. A thermostatic bin control<br />

may be used on KML models and is required for some<br />

dispenser application.<br />

2.MECHANICAL BIN CONTROL:<br />

KML and some M models use a mechanical bin control.<br />

This control includes a proximity switch and actuator paddle<br />

assembly. The mechanical bin control assembly mounts in<br />

the ice drop zone area and will shut the unit dowm within 3<br />

seconds when ice pushes the actuator paddle to the full<br />

right position, away from the proximity switch. Shut down<br />

will only occur during the first 5 minutes of the freeze cycle<br />

when the paddle is moved away from the proximity switch.<br />

If the paddle is moved away from the proximity switch and<br />

held at any other time during the sequence, the unit will<br />

continue to run until the next freeze cycle occurs. This<br />

feature allows for a full batch of ice every cycle so that<br />

there are no small cubes in the bin.<br />

A resistor wireing harness connects the mechanical bin<br />

control to the red K4 connector on the control board. As the<br />

proximity switch opens and closes, the resistance value<br />

will change to either start up or shut down the unit.<br />

29<br />

12/01/02 12/20/03<br />

2/20/03