stores the data at a specified rate. A slide control on the front panel allows the user to set the<br />

target temperature <strong>for</strong> the heaters.<br />

Figure 4.4. Front panel of Labview program.<br />

The testing of the 48 in. sensor array demonstrated the effectiveness of the new measurement<br />

technology. Figure 4.5 shows the results of one test where the pile started at room temperature<br />

and was heated. When the sensors nearest the heater reached 50 degrees Celsius the heater was<br />

turned off. From the start of the test to the peak temperature took about three hours, and from<br />

there back to equilibrium took about seven hours. The eighth sensor, which was the last sensor<br />

on the first circuit board, was the furthest away from the heat source that registered a significant<br />

differential from the adjacent sensor. The test illustrated that the gradient measured along the<br />

pile was detected by the sensors in their complete array configuration, and the data was<br />

successfully stored <strong>for</strong> later processing. The test also illustrated that the sensor array responded<br />

in a timely manner to impressed thermal changes.<br />