4.3.10 Volts Setup<br />

VOLTS DISPLAY MAX:<br />

Select the maximum value that you want the volts bargraph in the <strong>EMS</strong> display to show. This can give you increased<br />

display resolution.<br />

VOLTS DISPLAY MIN:<br />

Select the minimum value that you want the volts bargraph in the <strong>EMS</strong> display to show. This can give you increased<br />

display resolution.<br />

HIGH ALARM:<br />

This enables or disables the volts high alarm.<br />

HIGH ALARM:<br />

Enter the voltage threshold for when the high alarm must be activated. Any voltage above this value will activate the<br />

alarm.<br />

HIGH CAUTION:<br />

Enter the voltage for the high caution. This is the lower value of the upper yellow band.<br />

LOW CAUTION:<br />

Enter the voltage for the low caution. This is the upper value of the lower yellow band.<br />

LOW ALARM:<br />

This enables or disables the volts low alarm.<br />

LOW ALARM:<br />

Enter the voltage threshold for when the low alarm must be activated. Any voltage below this value will activate the alarm.<br />

VOLTS CALIBRATION FACTOR:<br />

Measure the battery voltage with a multimeter and then adjust this value to match that of the multimeters volts reading.