<strong>XTreme</strong>-<strong>EMS</strong> Operating <strong>Manual</strong> Page 9<br />

3.1.4.4 Single/Differential/Summed fuel flow, single fuel level sender, single calculated tank<br />

These modes are nice for multiple fuel tanks whereby one or more tanks are difficult to insert level senders in. Potential<br />

problems such as those listed below can easily be diagnosed by doing side by side comparisons between a calculated<br />

and physical tank.<br />

• Leaks in the fuel system<br />

• Uneven drain of interconnected tanks<br />

• Malfunction of the level sender<br />

• Malfunction of the flow sender<br />

3.1.4.5 Single fuel flow only indicator<br />

This mode is displayed if either fuel flow 1 or fuel flow 2 is selected and no fuel level senders are selected.<br />

3.1.4.6 Dual fuel flow indicator<br />

This mode is displayed if both fuel flow 1 and fuel flow 2 is selected and the fuel mode is selected for dual flow. Both fuel<br />

level senders are disabled.<br />

3.1.4.7 Single tank level indicator<br />

This mode is displayed if either fuel level 1 or fuel level 2 is selected. Both fuel flow senders are disabled.