Name Type Comment<br />

VAR_IN_OUT ControlledAxis AXIS_REF Reference to the controlled axis.<br />

MeasuredAxis AXIS_REF Reference to the measured axis (used only for MLC).<br />

<strong>MLD</strong>-S provides only one axis, consequently the<br />

MeasuredAxis is equal with the Controlled axis.<br />

VAR_INPUT Enable BOOL Enables the Register Controller<br />

Pause BOOL The input "Pause" will only be evaluated while the<br />

"Enable" input is active. Pause is intended to keep the<br />

"ControlValue" constant in a steady state. In this case, the<br />

"Deviation" = Setpoint-ActualValue will be set to 0 causing<br />

the "ControlValue" to be fixed. Probe events are still<br />

monitored and the controlled parameter will still be<br />

affected.<br />

Preset BOOL The input Preset will only be evaluated while "Enable"<br />

AND "Pause" is TRUE. A positive edge of this input forces<br />

the I-fraction of the control loop to "PresetVal". In addition,<br />

this function sets the controlled parameter to the absolute<br />

value "PresetVal"<br />

Polarity BOOL The polarity of the control value is inverse as long this<br />

input is TRUE<br />

ProbeSelect PROBE_NUMBER Specify the selected probe input used for signal<br />

measurement:<br />

PROBE1 = 1: Probe 1 is selected,<br />

PROBE2 = 2: Probe 2 is selected<br />

ProbeEdge PROBE_EDGE Specify the selected probe edge for signal measurement:<br />

POS_EDGE = 1: Positive Edge is used<br />

NEG_EDGE = 2: Negative Edge is used<br />

ControlledValueIDN DINT Sercos-IDN of the controlled parameter. The following<br />

IDN's are supported: P-0-0691, P-0-0694, P-0-0695, S-0-<br />

0048, P-0-0061<br />

Setpoint REAL Desired value<br />

PControl REAL Proportional gain of the PI controller. If 0, the proportional<br />

part of the controller is disabled and the proportional gain<br />

is set internally to 1 in order to work as an I-Controller..<br />

IControl REAL Integral time Tn of the PI controller. If set to 0, the integral<br />

part of the PI-controller is disabled. Units [10 -2 ], like Synax<br />

parameter A-0-0092.<br />

SensorDeadTime REAL Dead time of the sensor in [us] used for dead time<br />

compensation of the measured signal<br />

HighLimit REAL This is the maximum value that ControlValue can have<br />

LowLimit REAL This is the minimum value that ControlValue can have<br />

PresetVal REAL This is the value fed to the system when the Preset<br />

function becomes active<br />

VAR_OUTPUT InOperation BOOL Registration controller is running<br />

Error BOOL Indicates an error. Clear error with “Enable” = FALSE<br />

ErrorID INT (Enum) ERROR_CODE: Short error description<br />

ErrorIdent ERROR_STRUCT Detailed error description<br />

PresetDone BOOL Preset function is done<br />

HighLimitAck BOOL High limit is active. ControlValue would be higher, but is<br />

limited to HighLimit<br />

LowLimitAck BOOL Low limit is active. ControlValue would be lower, but is<br />

limited to LowLimit<br />

Counter UINT Counter increases if probe was detected<br />

DOK-<strong>MLD</strong>-S*-<strong>Tech</strong><strong>FB</strong>*****-AW01-EN-D