1-36 <strong>MLD</strong>-S <strong>Tech</strong>nology <strong>Library</strong> <strong>Rexroth</strong> <strong>MLD</strong>-S <strong>Tech</strong>-<strong>FB</strong> <strong>Library</strong><br />
Name Type Comment<br />
VAR_IN_OUT ControlledAxis AXIS_REF Reference to the controlled axis.<br />
MeasuredAxis AXIS_REF Reference to the measured axis (used only for MLC).<br />
<strong>MLD</strong>-S provides only one axis, consequently the<br />
MeasuredAxis is equal with the Controlled axis.<br />
VAR_INPUT Enable BOOL Enables the Register Controller<br />
Pause BOOL The input "Pause" will only be evaluated while the<br />
"Enable" input is active. Pause is intended to keep the<br />
"ControlValue" constant in a steady state. In this case, the<br />
"Deviation" = Setpoint-ActualValue will be set to 0 causing<br />
the "ControlValue" to be fixed. Probe events are still<br />
monitored and the controlled parameter will still be<br />
affected.<br />
Preset BOOL The input Preset will only be evaluated while "Enable"<br />
AND "Pause" is TRUE. A positive edge of this input forces<br />
the I-fraction of the control loop to "PresetVal". In addition,<br />
this function sets the controlled parameter to the absolute<br />
value "PresetVal"<br />
Polarity BOOL The polarity of the control value is inverse as long this<br />
input is TRUE<br />
ProbeSelect PROBE_NUMBER Specify the selected probe input used for signal<br />
measurement:<br />
PROBE1 = 1: Probe 1 is selected,<br />
PROBE2 = 2: Probe 2 is selected<br />
ProbeEdge PROBE_EDGE Specify the selected probe edge for signal measurement:<br />
POS_EDGE = 1: Positive Edge is used<br />
NEG_EDGE = 2: Negative Edge is used<br />
ControlledValueIDN DINT Sercos-IDN of the controlled parameter. The following<br />
IDN's are supported: P-0-0691, P-0-0694, P-0-0695, S-0-<br />
0048, P-0-0061<br />
Setpoint REAL Desired value<br />
PControl REAL Proportional gain of the PI controller. If 0, the proportional<br />
part of the controller is disabled and the proportional gain<br />
is set internally to 1 in order to work as an I-Controller..<br />
IControl REAL Integral time Tn of the PI controller. If set to 0, the integral<br />
part of the PI-controller is disabled. Units [10 -2 ], like Synax<br />
parameter A-0-0092.<br />
SensorDeadTime REAL Dead time of the sensor in [us] used for dead time<br />
compensation of the measured signal<br />
HighLimit REAL This is the maximum value that ControlValue can have<br />
LowLimit REAL This is the minimum value that ControlValue can have<br />
PresetVal REAL This is the value fed to the system when the Preset<br />
function becomes active<br />
VAR_OUTPUT InOperation BOOL Registration controller is running<br />
Error BOOL Indicates an error. Clear error with “Enable” = FALSE<br />
ErrorID INT (Enum) ERROR_CODE: Short error description<br />
ErrorIdent ERROR_STRUCT Detailed error description<br />
PresetDone BOOL Preset function is done<br />
HighLimitAck BOOL High limit is active. ControlValue would be higher, but is<br />
limited to HighLimit<br />
LowLimitAck BOOL Low limit is active. ControlValue would be lower, but is<br />
limited to LowLimit<br />
Counter UINT Counter increases if probe was detected<br />
DOK-<strong>MLD</strong>-S*-<strong>Tech</strong><strong>FB</strong>*****-AW01-EN-D