Fig. 1-64: WeightedAdjustment<br />

Note:<br />

When a time interval = 0, so the next weighting factor is used<br />

until the adjustment process aborts. Example: If<br />

AdjTimeIntervals[2] = 0, then the weighting factor of<br />

AdjWeightFactors[3] is used until abortion.<br />

To determine the correct time interval of the weighting factors, the expired<br />

time is reset with each new starting adjustment process. If inputs<br />

„AdjWeightFactors“ and „AdjTimeIntervals“ are not set, a continuous<br />

adjustment with the given alteration velocity specified with<br />

„StepsPerSecond“ and „StepWidth“ occurs.<br />

Note:<br />

Values in “AdjTimeIntervals“ must only contain positive values.<br />

Weighting factors can be positive or negative.<br />

The influenced variable can only be set to the specified preset<br />

value if it is within the valid range between „HighLimit“ and<br />

„LowLimit“.<br />

Output „InOperation“ signals that the block is in use, but an adjustment is<br />

not active. " Changing" indicates an error-free adjustment and the value of<br />

the adjusted variable „Value“ is valid.<br />

“Error“ indicates that an error occurred during the adjustment process.<br />

Details are indicated in the „ErrorIdent“ structure.<br />

Errorhandling<br />

The function block generates the following error messages<br />

Additional1/Additional2 of the table "F_RELATED_TABLE", 16#0170:<br />

in<br />

ErrorID Additional1 Additional2 <strong>Description</strong><br />

INPUT_RANGE_ERROR<br />

(16#0006)<br />

16#0002 16#0000 Inputs are outside permitted range<br />

RESOURCE_ERROR (16#0003) 16#0004 16#0000 Drive firmware not supported.<br />

STATE_MACHINE_ERROR<br />

(16#0005)<br />

16#0006 16#0000 Invalid status of the function block<br />

Fig. 1-65 Error numbers, caused by MX_ContinuousAdjustType01<br />

Required Hardware<br />

Required Software<br />

Required Parameterization<br />

Required IndraLogic Steps<br />

• IndraDrive C or M (MPx03 Firmware)<br />

• IndraWorks Drive with IndraLogic<br />

• No special parameterization required<br />

• Include library ML(X)_<strong>Tech</strong>nology.lib in the IndraLogic-Project<br />

DOK-<strong>MLD</strong>-S*-<strong>Tech</strong><strong>FB</strong>*****-AW01-EN-D