Section 4<br />
Exhaust & Aftertreatment<br />
Horizontal (Crossover) DPF and SCR with Rectangular Small or Medium DEF Tanks<br />
FIGURE 4-5: Horizontal Exhaust with Small or Medium Tanks.<br />
The height differential between the supply module and dosing module cannot exceed one meter. The supply module is<br />
integrated into the DEF tank assembly, separation of the module frm the tank is not allowed.<br />
When relocating the components the maximum pressure DEF hose length, from Supply module to Dosing Module is<br />
3 meters (118”).<br />
Vertical DPF and SCR with Rectangular Small or Medium DEF Tanks<br />
FIGURE 4-6: Vertical Exhaust with Small or Medium Tanks.<br />
The height differential between the supply module and dosing module can not exceed one meter. The supply module is<br />
integrated into the DEF tank assembly, separation of the module from the tank is not allowed.<br />
When relocating the components the maximum pressure DEF hose length, from Supply module to Dosing Module, is 3<br />
meters (118”).<br />
12/09 4-6