© Edwards Limited 2007. All rights reserved. Page 9<br />

Edwards <strong>and</strong> the Edwards logo are trade marks of Edwards Limited.<br />

Parameter <strong>Unit</strong>s<br />

Gas-ballast control closed (position ‘0’)<br />

Table 4 - Performance data: High Throughput mode<br />

HIGH THROUGHPUT MODE �<br />

RV3 RV5 RV8 RV12<br />

1-phase 3-phase 1-phase 3-phase 1-phase 3-phase 1-phase 3-phase<br />

Ultimate total pressure mbar 3 x 10 -2 3x10 -2 3x10 -2 3x10 -2<br />

Gas-ballast control low flow (position ‘I’)<br />

Pa 3 3 3 3<br />

Ultimate total pressure mbar 6 x 10 -2 6x10 -2 4x10 -2 4x10 -2<br />

Pa 6 6 4 4<br />

Gas-ballast flow l min -1 5 5 5 5<br />

Maximum water vapour pumping rate kg h -1 0.06 0.04 0.06 0.04 0.06 0.04 0.06 0.04<br />

Maximum water vapour inlet pressure mbar 27 18 16 11 10 7 7 5<br />

Gas-ballast control high flow (position ‘II’)<br />

Pa 2.7 x 10 3 1.8 x 10 3 1.6 x 10 3 1.1 x 10 3 1x10 3 7x10 2 7x10 2 5x10 2<br />

Ultimate total pressure mbar 1.2 x 10 -1 1x10 -1 6x10 -2 6x10 -2<br />

Pa 1.2 x 10 1 1x10 1 6 6<br />

Gas-ballast flow l min -1 14 14 16 16<br />

Maximum water vapour pumping rate kg h -1 0.22 0.12 0.22 0.12 0.22 0.20 0.29 0.25<br />

Maximum water vapour inlet pressure mbar 80 54 50 32 38 34 32 28<br />

Pa 8 x 10 3 5.4 x 10 3 5x10 3 3.2 x 10 3 3.8 x 10 3 3.4 x 10 3 3.2 x 10 3 2.8 x 10 3<br />

Technical data<br />

A652–01–880 Issue S