5.8 Clean the motor fan-cover <strong>and</strong> enclosure<br />

If the motor fan-cover <strong>and</strong> enclosure are not kept clean, the air-flow over the motor can be restricted <strong>and</strong> the pump<br />

may overheat.<br />

1. Switch off the pump <strong>and</strong> disconnect it from the electrical supply.<br />

2. Use a dry cloth <strong>and</strong> a soft brush to remove dirt <strong>and</strong> deposits from the fan-cover <strong>and</strong> enclosure.<br />

5.9 Clean <strong>and</strong> overhaul the pump<br />

Clean <strong>and</strong> overhaul the pump as described in the instructions supplied with the clean <strong>and</strong> overhaul kit (see<br />

Section 7.3).<br />

5.10 Fit new blades<br />

Fit new blades to the pump as described in the instructions supplied with the blade kit (see Section 7.3).<br />

5.11 Test the motor condition<br />

Test the earth (ground) continuity <strong>and</strong> the insulation resistance of the pump-motor, in accordance with local<br />

regulations for periodic testing of electrical equipment.<br />

The motor of single-phase RV pumps complies with IEC 1010–1. We recommend that, to maintain compliance with<br />

IEC 1010–1, the earth continuity is less than 0.1 Ω <strong>and</strong> the insulation resistance is greater than 10 MΩ.<br />

If the motor fails these tests, you must replace the motor.<br />

5.12 Fault-finding<br />

5.12.1 Introduction<br />

A list of fault conditions <strong>and</strong> their possible causes is provided in the following sections to assist you in fault-finding.<br />

If you are unable to rectify a fault when you use this guide, call your nearest Edwards Service Centre for help.<br />

5.12.2 The pump has failed to start<br />

� The electrical supply fuse has failed<br />

� The electrical supply voltage does not match that of the motor<br />

� The outlet pipeline or the outlet-filter (if fitted) is blocked<br />

� The oil temperature is below 12°C<br />

� The oil is too viscous<br />

� The oil is contaminated<br />

� The pump has seized after long storage<br />

� The pump has been left to st<strong>and</strong> after contaminants have been pumped <strong>and</strong> has seized<br />

� The motor is faulty.<br />

Page 38 © Edwards Limited 2007. All rights reserved.<br />