09.03.2015 Views

VSAN-Troubleshooting-Reference-Manual

VSAN-Troubleshooting-Reference-Manual

VSAN-Troubleshooting-Reference-Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Diagnostics and <strong>Troubleshooting</strong> <strong>Reference</strong> <strong>Manual</strong> – Virtual SAN<br />

Revision: 3.66<br />

SCSI Level: 5<br />

Is Pseudo: false<br />

Status: degraded<br />

Is RDM Capable: true<br />

Is Local: false<br />

Is Removable: false<br />

Is SSD: false<br />

Is Offline: false<br />

Is Perennially Reserved: false<br />

Queue Full Sample Size: 0<br />

Queue Full Threshold: 0<br />

Thin Provisioning Status: unknown<br />

Attached Filters:<br />

VAAI Status: unknown<br />

Other UIDs: vml.0200060000600508b1001c4b820b4d80f9f8acfa954c4f47494341<br />

Is Local SAS Device: false<br />

Is USB: false<br />

Is Boot USB Device: false<br />

No of outstanding IOs with competing worlds: 32<br />

eui.a15eb52c6f4043b5002471c7886acfaa<br />

Display Name: Local FUSIONIO Disk (eui.a15eb52c6f4043b5002471c7886acfaa)<br />

Has Settable Display Name: true<br />

Size: 1149177<br />

Device Type: Direct-Access<br />

Multipath Plugin: NMP<br />

Devfs Path: /vmfs/devices/disks/eui.a15eb52c6f4043b5002471c7886acfaa<br />

Vendor: FUSIONIO<br />

Model: IODRIVE<br />

Revision: v1.0<br />

SCSI Level: 5<br />

Is Pseudo: false<br />

Status: on<br />

Is RDM Capable: false<br />

Is Local: true<br />

Is Removable: false<br />

Is SSD: true<br />

Is Offline: false<br />

Is Perennially Reserved: false<br />

Queue Full Sample Size: 0<br />

Queue Full Threshold: 0<br />

Thin Provisioning Status: yes<br />

Attached Filters:<br />

VAAI Status: unknown<br />

Other UIDs: vml.0100000000313231304430393235494f44524956<br />

Is Local SAS Device: false<br />

Is USB: false<br />

Is Boot USB Device: false<br />

No of outstanding IOs with competing worlds: 32<br />

There is a lot of useful information to be gleaned from this output. One can see that<br />

the magnetic disks (Is SSD: false) seems to be presented to the ESXi host from a HP<br />

controller (Vendor: HP), and we can see the flash device (Is SSD: true) seems to be<br />

presented from a Fusion-IO controller.<br />

Note that the status of the magnetic disk shown as degraded in the above output.<br />

The reason for this is because there is only a single path to the device. If there were<br />

multiple paths, then this “degraded" state is not present. This is not a concern for<br />

local disks, as in almost all local disk configurations, there will only be one path to<br />

the devices.<br />

V M W A R E S T O R A G E B U D O C U M E N T A T I O N / 27