Diagnostics and <strong>Troubleshooting</strong> <strong>Reference</strong> <strong>Manual</strong> – Virtual SAN<br />

Using fio-status (Fusion-IO command) to check settings<br />

The final thing to check is the firmware version of the Fusion-IO device. There does<br />

not appear to be an ESXCLI command to display this information. Fortunately<br />

Fusion-IO has provided such a tool and it is installed on the ESXi host along with the<br />

other software components from Fusion-IO. This command provides driver version,<br />

firmware version and product number, which is what is listed on the VCG.<br />

~ # fio-status<br />

Found 1 ioMemory device in this system<br />

Driver version: 3.2.8 build 1350<br />

Adapter: Single Controller Adapter<br />

Fusion-io ioDrive2 1.205TB, Product Number:F00-001-1T20-CS-0001, SN:1210D0925,<br />

FIO SN:1210D0925<br />

External Power: NOT connected<br />

PCIe Power limit threshold: 24.75W<br />

Connected ioMemory modules:<br />

fct0: Product Number:F00-001-1T20-CS-0001, SN:1210D0925<br />

fct0<br />

Attached<br />

ioDrive2 Adapter Controller, Product Number:F00-001-1T20-CS-0001, SN:1210D0925<br />

Located in slot 0 Center of ioDrive2 Adapter Controller SN:1210D0925<br />

PCI:0b:00.0<br />

Firmware v7.1.15, rev 110356 Public<br />

1205.00 GBytes device size<br />

Internal temperature: 55.12 degC, max 58.08 degC<br />

Reserve space status: Healthy; Reserves: 100.00%, warn at 10.00%<br />

Contained VSUs:<br />

fioiom0: ID:0, UUID:a15eb52c-6f40-43b5-8a48-84c7886acfaa<br />

fioiom0 State: Online, Type: block device<br />

ID:0, UUID:a15eb52c-6f40-43b5-8a48-84c7886acfaa<br />

1205.00 GBytes device size<br />

There is now enough information gathered (model, vendor, driver, firmware) that<br />

supportability might be checked on the VMware Compatibility Guide for Virtual SAN.<br />