VSAN-Troubleshooting-Reference-Manual
VSAN-Troubleshooting-Reference-Manual
VSAN-Troubleshooting-Reference-Manual
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Diagnostics and <strong>Troubleshooting</strong> <strong>Reference</strong> <strong>Manual</strong> – Virtual SAN<br />
WHAT HAPPENS WHEN THE ENTIRE CLUSTER NETWORK FAILS? ................................................................. 71<br />
WHAT HAPPENS WHEN A STORAGE I/O CONTROLLER FAILS? ...................................................................... 71<br />
HANDLING MULTIPLE FAILURES ......................................................................................................................... 72<br />
8. GETTING STARTED WITH RVC .................................................................................................... 73<br />
INTRODUCTION TO RVC AND <strong>VSAN</strong> OBSERVER .............................................................................................. 73<br />
RVC DEPLOYMENT SUGGESTION/RECOMMENDATION ................................................................................... 73<br />
LAUNCHING RVC FROM THE VCENTER SERVER APPLIANCE ......................................................................... 73<br />
LAUNCHING RVC FROM WINDOWS VCENTER SERVER .................................................................................. 77<br />
9. NAVIGATING RVC ............................................................................................................................. 79<br />
NAVIGATING RVC EXAMPLES .............................................................................................................................. 79<br />
USING RVC TO DISPLAY ADAPTER INFORMATION ........................................................................................... 81<br />
vsan.disks_info –show-adapters .................................................................................................................... 81<br />
USING RVC TO VERIFY VIRTUAL SAN FUNCTIONALITY ................................................................................. 81<br />
vsan.cluster_info .................................................................................................................................................... 82<br />
A note of fault domains ...................................................................................................................................... 83<br />
vsan.check_state .................................................................................................................................................... 84<br />
vsan.check_limits .................................................................................................................................................. 86<br />
Brief explanation on RDT Assocs/Sockets/Client/Owners ............................................................... 88<br />
Brief explanation of disk components revisited ..................................................................................... 88<br />
Understanding components and component count ............................................................................. 90<br />
Examining components via the vSphere web client ............................................................................. 90<br />
vsan.vm_object_info ............................................................................................................................................. 92<br />
vsan.object_info ..................................................................................................................................................... 93<br />
vsan.whatif_host_failures .................................................................................................................................. 94<br />
10. TROUBLESHOOTING THE VIRTUAL SAN NETWORK ......................................................... 95<br />
INTRODUCTION TO VIRTUAL SAN NETWORKING ........................................................................................... 96<br />
VIRTUAL SAN NETWORK REQUIREMENTS ........................................................................................................ 97<br />
Physical Network Interface Card (NIC) requirements ........................................................................ 97<br />
Virtual SAN traffic – vmknic requirement ................................................................................................ 97<br />
Virtual switch requirement ............................................................................................................................. 97<br />
MTU & jumbo frames .......................................................................................................................................... 98<br />
Multicast traffic requirement ......................................................................................................................... 98<br />
IGMP snooping and IGMP querier for multicast traffic ...................................................................... 99<br />
Using NIOC and VDS to set Quality of Service on Virtual SAN traffic ........................................ 100<br />
VIRTUAL SAN AND VSPHERE HA NETWORK DEPENDENCY ....................................................................... 101<br />
Changing the vSphere HA network ........................................................................................................... 101<br />
CHECKING THE VIRTUAL SAN NETWORK IS OPERATIONAL ....................................................................... 102<br />
esxcli vsan network list ................................................................................................................................... 102<br />
esxcli network ip interface list ..................................................................................................................... 103<br />
esxcli network ip interface ipv4 get –i vmk2 ........................................................................................ 103<br />
vmkping ................................................................................................................................................................. 104<br />
vsan.cluster_info ................................................................................................................................................. 104<br />
esxcli network ip neighbor list .................................................................................................................... 105<br />
esxcli network diag ping ................................................................................................................................ 105<br />
CHECKING MULTICAST SETTINGS..................................................................................................................... 106<br />
tcpdump-uw –i vmk2 udp port 23451 –v ............................................................................................... 106<br />
tcpdump-uw –i vmk2 igmp ........................................................................................................................... 107<br />
CHANGING MULTICAST SETTINGS WHEN MULTIPLE VIRTUAL SAN CLUSTERS ARE PRESENT .............. 108<br />
V M W A R E S T O R A G E B U D O C U M E N T A T I O N / 4