09.03.2015 Views

VSAN-Troubleshooting-Reference-Manual

VSAN-Troubleshooting-Reference-Manual

VSAN-Troubleshooting-Reference-Manual

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Diagnostics and <strong>Troubleshooting</strong> <strong>Reference</strong> <strong>Manual</strong> – Virtual SAN<br />

esxcli storage core device stats get ........................................................................................................... 140<br />

VERIFYING VIRTUAL SAN STORAGE OPERATION – RVC ............................................................................. 141<br />

vsan.check_state ................................................................................................................................................. 141<br />

vsan.disks_stats ................................................................................................................................................... 141<br />

VIRTUAL SAN DATASTORE SPACE MANAGEMENT ........................................................................................ 142<br />

Maintenance Mode ........................................................................................................................................... 142<br />

SSD, magnetic disk or host failure ............................................................................................................. 143<br />

Small disk drive capacity considerations ............................................................................................... 143<br />

Very large VMDK considerations ............................................................................................................... 144<br />

CHANGING A VM STORAGE POLICY DYNAMICALLY ...................................................................................... 144<br />

PROVISIONING WITH A POLICY THAT CANNOT BE IMPLEMENTED ............................................................. 145<br />

What happens when a threshold is reached? ....................................................................................... 145<br />

COMPONENT DISTRIBUTION ON VIRTUAL SAN ............................................................................................ 146<br />

Checking disk usage distribution with RVC – vsan.disks_stats ..................................................... 146<br />

Checking component distribution with RVC – vsan.disks_limits ................................................. 146<br />

PROACTIVELY BALANCING COMPONENT DISTRIBUTION WITH RVC ......................................................... 147<br />

vsan.proactive_rebalance .............................................................................................................................. 147<br />

VIRTUAL SAN FAILURE REMEDIATION – REBUILDING COMPONENTS ....................................................... 149<br />

vsan.resync_dashboard ................................................................................................................................... 150<br />

vsan.vm_object_info .......................................................................................................................................... 150<br />

vsan.resync_dashboard ................................................................................................................................... 151<br />

TESTING VIRTUAL SAN FUNCTIONALITY - DEPLOYING VMS ..................................................................... 152<br />

diagnostics.vm_create ..................................................................................................................................... 152<br />

diagnostics.vm_create failure – clomd not running .......................................................................... 152<br />

COMMON STORAGE PROBLEMS AND RESOLUTIONS ...................................................................................... 153<br />

Virtual SAN claiming disks but capacity not correct ........................................................................ 153<br />

Virtual SAN not claiming disks - existing partition information ................................................ 153<br />

esxcli vsan storage remove ........................................................................................................................... 154<br />

partedUtil .............................................................................................................................................................. 154<br />

Virtual SAN not claiming disks - Is Local: false ................................................................................... 154<br />

VIRTUAL SAN STORAGE DEVICE FAILURE OBSERVATIONS.......................................................................... 156<br />

Observations when a disk is failed/removed in a controlled manner ...................................... 156<br />

esxcli vsan storage list - unknown ............................................................................................................. 158<br />

vdq –qH: IsPDL.................................................................................................................................................... 159<br />

Observations when a flash device fails .................................................................................................... 160<br />

Observations when a storage controller fails....................................................................................... 161<br />

Storage controller replacement ................................................................................................................. 162<br />

Expectations when a drive is reporting errors .................................................................................... 162<br />

BLINKING LEDS ON DRIVES.............................................................................................................................. 163<br />

PREDICTIVE REPORTING - SMARTD ................................................................................................................. 164<br />

esxcli storage core device smart get ......................................................................................................... 164<br />

CONSIDERATIONS WHEN CLONING ON VIRTUAL SAN ................................................................................. 165<br />

A NOTE ABOUT <strong>VSAN</strong>SPARSE VIRTUAL DISK FORMAT .................................................................................. 165<br />

SUMMARY CHECKLIST FOR VIRTUAL SAN STORAGE .................................................................................... 166<br />

12. TROUBLESHOOTING VIRTUAL SAN UPGRADES................................................................ 167<br />

VIRTUAL SAN UPGRADE - ON-DISK FORMAT V2 ........................................................................................... 167<br />

Before you start upgrading the on-disk format .................................................................................. 167<br />

On-disk format upgrade pre-check: vsan.disks_stats ........................................................................ 168<br />

On-disk format upgrade: vsan.v2_ondisk_upgrade ........................................................................... 169<br />

V M W A R E S T O R A G E B U D O C U M E N T A T I O N / 6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!