PROGRAMMING - chap.6<br />
Technical manual<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
10<br />
from<br />
11<br />
to<br />
17<br />
control machine alarms<br />
Display of the NN number of alarms due to maximum boiler<br />
filling time being exceeded.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to minimum level of<br />
water in the boiler.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to the boiler sensor<br />
not working.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to blockage of the<br />
group 1 piston.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to the lack of coffee<br />
in group 1.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to the volumetric<br />
counter of group 1 not working.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to insufficient<br />
compression of group 1.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to overtemperature<br />
of group 1.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to the group 1<br />
compression microswitch.<br />
Press ENTER to go to the next check.<br />
Display of the NN number of alarms due to non-conforming<br />
grinding of group 1.<br />
Press ENTER to go to the next check.<br />
To check group 2 alarms, proceed in the same way as described<br />
above.<br />
zero setting of the alarms<br />
24<br />
english<br />
minimum level<br />
IN the boiler nn<br />
boiler sensor<br />
not active nn<br />
piston motor gr.1<br />
BLOCked nn<br />
not coffee<br />
GROUP 1 nn<br />
volum doser GR.1<br />
does not count nn<br />
insufficient GR 1<br />
compression nn<br />
over temperature<br />
GRoUP 1 nn<br />
MICRO<br />
COMPRESSION GR.1 nn<br />
grinding GR 1<br />
NOt correct nn<br />
c.t. .................. erog. s. GR nnn 2<br />
.......................... NN<br />
While each alarm is displayed it is possible to revert to zero the relative number by keeping the ARROW key<br />
pressed for at least 5 seconds until the message is displayed (example)<br />
water level<br />
in the boiler<br />
TOT. 0000<br />
water level<br />
IN the boiler nn