PROGRAMMING - chap.6<br />

Technical manual<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

from<br />

11<br />

to<br />

17<br />

control machine alarms<br />

Display of the NN number of alarms due to maximum boiler<br />

filling time being exceeded.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to minimum level of<br />

water in the boiler.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to the boiler sensor<br />

not working.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to blockage of the<br />

group 1 piston.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to the lack of coffee<br />

in group 1.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to the volumetric<br />

counter of group 1 not working.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to insufficient<br />

compression of group 1.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to overtemperature<br />

of group 1.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to the group 1<br />

compression microswitch.<br />

Press ENTER to go to the next check.<br />

Display of the NN number of alarms due to non-conforming<br />

grinding of group 1.<br />

Press ENTER to go to the next check.<br />

To check group 2 alarms, proceed in the same way as described<br />

above.<br />

zero setting of the alarms<br />

24<br />

english<br />

minimum level<br />

IN the boiler nn<br />

boiler sensor<br />

not active nn<br />

piston motor gr.1<br />

BLOCked nn<br />

not coffee<br />

GROUP 1 nn<br />

volum doser GR.1<br />

does not count nn<br />

insufficient GR 1<br />

compression nn<br />

over temperature<br />

GRoUP 1 nn<br />

MICRO<br />

COMPRESSION GR.1 nn<br />

grinding GR 1<br />

NOt correct nn<br />

c.t. .................. erog. s. GR nnn 2<br />

.......................... NN<br />

While each alarm is displayed it is possible to revert to zero the relative number by keeping the ARROW key<br />

pressed for at least 5 seconds until the message is displayed (example)<br />

water level<br />

in the boiler<br />

TOT. 0000<br />

water level<br />

IN the boiler nn