display<br />

volum doser gr1 - 2<br />

does not count<br />

overtemperature<br />

sensor group i - 2<br />

cause remedy<br />

1. Coffee ground too fine<br />

2. Water flow obstructed somewhere<br />

along the hydraulic circuit (volumetric<br />

dosing device, gicleur group)<br />

3. Flowmeter is broken or unproperly<br />

connected (the LED on the flowmeter<br />

fails to flash during dispensing)<br />

1. Temperature probe failure<br />

2. Short circuit of probe connection<br />

cables<br />

3. Faulty relay on the driver board<br />

4. Wrong temperature setting<br />

1. Group temperature sensor is<br />

either faulty or the connection is<br />

interrupted<br />

51<br />

english<br />

1. Restore connection<br />

and/or change the<br />

temperature sensor if<br />

necessary<br />

2. Press the key<br />

Technical manual<br />

1. Increase coarseness with the ring nut<br />

2. Enter the “Actuator Test” in machine<br />

programming and find where the blockage<br />

is (group solenoid valve or motor pump).<br />

Eliminate blockage either by cleaning or<br />

changing the part.<br />

3. Position the connector correctly on the<br />

flowmeter and verify the state of the<br />

connecting cables. If necessary replace<br />

the flowmeter.<br />

1. Replace the<br />

temperature<br />

probe<br />

2. Check proper connection of probe<br />

3. Replace the driver board<br />

4. Reset the temperature<br />

TROUBLESHOOTING - chap.10